Page 1-36 Check Every 140 Hours (Once a Week) ∗ When the nozzle changer (option) is installed, clean it. Clean the top face of the nozzle changer with a cloth which is soaked with absolute alcohol. ∗ Be careful not to co…

Page 1-35
REGULAR
MAINTENANCE
1
444C-E-MMA01-A05-05
444C-410P
Air ejector
Nozzle taper face
444C-413P
444C-411P
444C-412P
Nozzle tip
Check Every 140 Hours (Once a Week)
b. Cleaning the nozzle
1. Remove dust in the air pass of the
nozzle with the air ejector.
∗ Blow the air to the nozzle tip.
At this time, be careful not to touch the nozzle
tip with an air ejector. It may damage the
nozzle tip.
2. Clean the nozzle taper face with a
cloth.
∗ Be careful not to leave the fiber on it.
3. Clean the nozzle tip (nozzle) with a
cloth.
4. Clean the nozzle reflector with a cloth.
∗ Do not use any solvent because it may cause
discoloration, deformation and peeling of the
glue of the nozzle reflector.
∗ The nozzle is not allowed to accept an ultra-
sonic cleaning. If it accepts the ultrasonic
cleaning, the nozzle reflector will corrode to
cause a chip recognition error.
Nozzle
reflector

Page 1-36
Check Every 140 Hours (Once a Week)
∗ When the nozzle changer (option) is installed, clean it.
Clean the top face of the nozzle
changer with a cloth which is soaked
with absolute alcohol.
∗ Be careful not to contaminate the contact faces
of it and the nozzle reflector.
∗ Check for the foreign body caught in the gap in
the shutter.
5. Setting (replacing) the vacuum filter
1. Put the filter on the firm face of the
table, etc., fit it pressing the holder.
2. Push the filter into the holder by the
convex part at the bottom of the pull-
ing jig.
∗ Ensure that the filter fits in the holder by
pressing it lightly by the convex part.
Shutter
444C-E-MMA01-A05-03
444C-458E
Filter
(Round side faces upward.)
Pulling jig
Convex part
Holder
444C-459E
444C-489P

Page 1-37
REGULAR
MAINTENANCE
1
Check Every 140 Hours (Once a Week)
444C-E-MMA01-A05-04
444C-406E
444C-421P
Nozzle holder
Spring for clamp
arm holder
Clamp arm
Nozzle
444C-422P
7. Checking the nozzle arrangement and setting the nozzle
a. Setting the nozzle to the nozzle holder
1. Set the nozzle to the nozzle holder.
∗ Hold the edge of the nozzle reflector and push
it upward the nozzle holder.
∗ The clamp arm may be taken off by pushing
the nozzle sideways.
6. Cleaning the holder of the transfer head
1. Clean the fixing groove (which is
reverse L-shaped) on the transfer
head with a swab.
2. Wipe the circumference of the tip of
the guide shaft section on the nozzle
holder with a cloth.
∗ Use a lint-free cloth.
Fixing groove
Guide shaft of nozzle holder
444C-517P