100%1 / 158
Page 1-89
REGULAR
MAINTENANCE
1
444C-E-MMA01-A09-03
Check Every 12000 Hours (Once Two Years)
4. Remove the wiring connected to the
valve.
Write down the setting position and wiring
name. The setting working will be smooth.
5. Remove the pipe (tube) connected to
the valve (manifold).
Write down the setting position and order. The
setting work will be smooth.
6. Remove the 2 bolt setting the bulb
(manifold).
7. Replace it with a new valve, and fix it
by the valve.
To the next page
444C-500P
444C-501P
444C-502P
Page 1-90
444C-E-MMA01-A09-05
Check Every 12000 Hours (Once Two Years)
8. Connect the pipe and wiring as be
recorded.
9. Set the head cover.
10. Turn ON the power.
11. Press
Machine
adjust
.
The Machine adjustment menu screen
appears.
12. Press Return to origin .
Returning to origin is performed.
To the next page
Page 1-91
REGULAR
MAINTENANCE
1
444C-E-MMA01-A09-04
Check Every 560 Hours (Once a Month)
13. Press
UNLOCK
+
START
.
14. Press Output check .
•“Output check screen is displayed.
15. Select the operation position (the
table with the transfer head of which
the vacuum pressure is to be mea-
sured).
To the next page