Select the concerned locations in the next dialog box and click the Start button. ►
Figure 5-3: Selecting locations
The calibration steps of the automatic calibration are now performed sequentially.

SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
33
Figure 5-4: Performing calibration steps
All tables with SIPLACE BulkFeeder X feeders on the selected locations are now calibrated, i.e. the
two fiducials are measured to determine the table position in the machine. After that, the feeder
position itself is detected and so also the glass plate position. Then the height calibration is
performed during which four points on the glass plate are measured. Finally, the position of the
internal feeder camera is calibrated, i.e. the offset between feeder camera and board camera.
When all calibration steps have been successfully performed, click on Accept to finish the ►
calibration.