00198045-01_OM_BulkFeeder_X_EN.pdf - 第41页

SIPLACE BulkFeede r X / Operating Ma nual 05/2017 Edition 41 NOTICE Repeating the cleaning procedu re If the glass plat e was dirty for a long ti me and has not been cl eaned it may happen that the result is not satisfac…

100%1 / 48
SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
40
5.7 Cleaning the Glass Plate
If it was not possible to clear or clean the glass plate by performing the actions in section 5.6
Clearing the Glass Plate, it has to be cleaned outside the machine.
For this, the glass plate has to be removed from the Cartridge and dipped into a cleaning agent.
The following cleaning set is required for the cleaning process:
Can with distilled water
Bottle with nozzle for distilled water
Cleaning agent CB 100 Alu
Tweezers
Glass disk for cleaning agent
Glass disk for distilled water
Remove the Cartridge from the Base Unit as described in section 5.5.1 Unlocking the
Cartridge.
Turn the Cartridge upside-down.
Figure 5-7: Removing the glass plate
Pour some cleaning agent into the glass disk.
Remove the three screws of the glass plate holder from the underside of the Cartridge.
Pull out the glass plate from the holder with the tweezers and put it into the glass disk.
Dip the glass plate into the cleaning agent for one hour.
Fill the bottle with nozzle with distilled water from the can.
Remove the glass plate from the glass disk with the tweezers and put it into the glass disk.
Rinse the glass plate thoroughly with distilled water from the bottle.
If the cleaning effect does not seem sufficient at a first check you may also use a water jet
and/or rub the glass plate with a lint-free cloth.
Dry the glass plate with a lint-free cloth.
SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
41
NOTICE
Repeating the cleaning procedure
If the glass plate was dirty for a long time and has not been cleaned it may happen that
the result is not satisfactory. In this case the cleaning procedure has to be repeated, i.e.
dipping the glass plate into the cleaning agent for one more hour.
Put back the glass plate into the glass plate holder with the tweezers.
NOTICE
Inserting the glass plate
Note the location when inserting the glass plate. The components will be transported on
the less reflective side.
Fasten the three screws of the glass plate holder on the underside of the Cartridge.
NOTICE
Fasten the screws
Fasten the three screws with care. Torque 0,05 0,1 Nm
Turn the Cartridge back again.
Insert the Cartridge on the Base Unit as describe d in section 5.4 Replacing the Cartridge on
the Base Unit.
SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
42
5.8 Exchanging the Glass Plate
If cleaning the glass plate fails, it has to be exchanged.
Remove the Cartridge from the Base Unit as described in section 5.5.1 Unlocking the
Cartridge.
Turn the Cartridge upside-down.
Figure 5-8: Removing the glass plate
Remove the three screws of the glass plate holder from the underside of the Cartridge.
Pull out the glass plate from the holder with the tweezers contained in the cleaning set.
Put the new glass plate into the glass plate holder with the tweezers.
Fasten the three screws of the glass plate holder on the underside of the Cartridge.
Turn the Cartridge back again.
Insert the Cartridge on the Base Unit as described in section 5.4 Replacing the Cartridge on the
Base Unit.