00198045-01_OM_BulkFeeder_X_EN.pdf - 第43页
SIPLACE BulkFeede r X / Operating Ma nual 05/2017 Edition 43 5.9 Maintaining the Plate Shu tter The ball bearings sho uld be relubricat ed, when the mi leage of 20% is reach ed. A rough cleanin g of parts is carried out …

SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
42
5.8 Exchanging the Glass Plate
If cleaning the glass plate fails, it has to be exchanged.
Remove the Cartridge from the Base Unit as described in section 5.5.1 Unlocking the ►
Cartridge.
Turn the Cartridge upside-down. ►
Figure 5-8: Removing the glass plate
Remove the three screws of the glass plate holder from the underside of the Cartridge. ►
Pull out the glass plate from the holder with the tweezers contained in the cleaning set. ►
Put the new glass plate into the glass plate holder with the tweezers. ►
Fasten the three screws of the glass plate holder on the underside of the Cartridge. ►
Turn the Cartridge back again. ►
Insert the Cartridge on the Base Unit as described in section 5.4 Replacing the Cartridge on the ►
Base Unit.

SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
43
5.9 Maintaining the Plate Shutter
The ball bearings should be relubricated, when the mileage of 20% is reached. A rough cleaning of
parts is carried out at the same time.
Dismantling the downholder and plate shutter
Remove the two fixing screws with a hexagon socket spanner size 1.3. ►
NOTICE
The fitting is pretensioned with a spring. Loose of parts is possible.
Remove the downholder and the screw socket. ►
Cleaning the ball bearing, sliding surfaces and shutter plate
The ball bearings are rinsed in the built-in state.
Press alcohol through the opening into the ball bearings. ►
Remove rest alcohol and soiling with compressed air. ►
Repeat this procedure 2-3 times. ►
Clean the sliding surfaces and shutter plate with a cotton wool tip and alcohol. ►
Lubrication of the ball bearings
Fill LUBCON Thermoplex ALN 1001/00 [03078556-xx] in the middle of the ball bearing, by ►
using the multi-nozzle from Eppendorf [00386154-xx] (inside the service bag).
Spread the grease in the ball bearing by rotating and by using a toothpick. ►
Assembly Instruction
Fit the parts in reverse order. ►

SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
44
5.10 Component Test Functions with Internal Feeder Camera
In the SIPLACE Vision live image tab, the current Vision image is displayed. A new image can be
taken by clicking on the Capture new image button.
Figure 5-9: Feeder details – Teaching dialog
The components can be taught in the corresponding teaching dialog for the feeder. Please refer to
the SIPLACE Vision online help for more information about the teaching process.
NOTICE
The Settings tab is only for settings during development.