00198045-01_OM_BulkFeeder_X_EN.pdf - 第48页

Item - no. / Artikel - Nr.: 00198045 - 01 ASM Assembly Systems GmbH & Co. KG Rupert - Ma yer -St raß e 44 81379 München Deutschland www.asm -smt.com

100%1 / 48
SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
46
6 Troubleshooting
Two types of errors may occur when you are working with the SIPLACE BulkFeeder X:
Hardware errors
Process errors
Hardware errors are issued by the feeder and process errors by the station software. The
corresponding error messages are listed below.
Generally, the status display LED on the Base Unit lights up red if an error occurs.
6.1 Hardware Error Messages
Hardware errors are displayed on the 7-segment display of the control panel as:
Er/Error no (e.g. Er/01 for error number 01).
The following error messages may be displayed.
Error no. Error description Correction
01 Locking mechanism is still outside after
power ON and initialization
Push in locking mechanism
02 Booting has been stopped during
initialization as an unsupported version
of a hardware module has been
detected
Hardware configuration error (not possible
at customer site)
03 Saving runtime data to the flash did not
succeed
Hardware error => send to manufacturer
for repair
07 The CAN controller is in error state BUS
OFF
Switch the machine off and on; check the
light conductor in EDIF
08 Max. processor temperature has been
exceeded
Hardware error => send to manufacturer
for repair
09 Data flash of the processor is defective Hardware error => send to manufacturer
for repair
11 Cartridge is not inserted correctly Check whether the Cartridge is inserted
correctly or removed from the Base Unit
12 Cartridge identification could not be read Hardware error
17 Max. vibration actuator temperature
exceeded (calculated in eSW)
(Should not occur in regular placement
mode)
18 Max. coil driver temperature has been
exceeded
Hardware error => send to manufacturer
for repair
19 Acceleration sensor on cube has
detected a shock
Not used so far
25 Plate shutter or container locking control
timeout (eSW error)
Hardware error => send to manufacturer
for repair
SIPLACE BulkFeeder X / Operating Manual 05/2017 Edition
47
26 Plate shutter did not reach target position Close the plate shutter.
Remove the Cartridge, check that the plate
shutter is able to move freely; if necessary,
clean the plate shutter mechanism
27 No index signal found while plate shutter
was referencing
Hardware error => send to manufacturer for
repair
28 Container locking did not reach target
position
Remove Cartridge manually, check
cartridge locking mechanism
29 Container shutter control timeout (eSW
error)
Hardware error => send to manufacturer for
repair
30 Container shutter did not reach target
position
Remove the Cartridge, check that the
container shutter is able to move freely; if
necessary, clean the container shutter
mechanism
31 Index position not found while container
shutter was referencing
Hardware error => send to manufacturer for
repair
32 No index signal found while container
locking was referencing
Hardware error => send to manufacturer for
repair
Figure 6-1: Hardware error messages
6.2 Process Error Messages
Process errors are displayed on the station software GUI. Please refer to the detailed information in
the online help of the station software if process errors occur.
Item-no. / Artikel-Nr.: 00198045-01
ASM Assembly Systems GmbH & Co. KG
Rupert-Mayer-Straße 44
81379 München
Deutschland
www.asm-smt.com