4-4
4
Maintenance of options
5
Supply the air and power on the ionizer.
1. Turn the air supply/exhaust switch and supply the air to the machine.
2. Close the machine safety cover and press the [READY] button.
3.
Check that the green LED of the "POWER" on the ionizer is turned on. Make sure that no error is found.
n
NOTE
If continuing to receive the error even after replacing the discharge needle unit, contact YAMAHA or YAMAHA sales
representatives.
n
NOTE
See the manufacturer's instructions for detailed specifications of the ionizer.
4-5
4
Maintenance of options
2. UPS (Uninterruptible Power Supply)
2.1 Replacing the UPS battery (3-year)
The battery is a consumable item. Even though the service life of the UPS may vary depending on the operating
environment, such as ambient temperature, it is recommended to replace the battery with a new one (KGA-
M6566-30X) at reference intervals of 3 years. The following describes how to replace the battery that is
incorporated into the UPS.
w
WARNING
BATTERY REPLACEMENTS SHOULD BE PERFORMED ONLY BY THOSE WITH ELECTRICAL WORK EXPERIENCE.
1
Turn the machine power OFF.
Turn OFF the UPS power several seconds
after turning OFF the machine power.
w
WARNING
DO NOT ATTEMPT THIS BATTERY REPLACEMENT
PROCEDURE WHILE THE MACHINE IS IN THE EMERGENCY
STOP STATUS OR THE UPS FUNCTION IS RUNNING.
2
Remove the front panel.
Use a Phillips screwdriver to remove the
screws which mount the front panel, then
remove the front panel.
53404-KMG-00
3
Disconnect the battery connector.
Disconnect the UPS side and internal battery
side connectors.
4
Remove the battery mounting
fixture.
Remove the battery fixture mounting screws,
then remove the battery mounting fixture.
5
Replace the removed battery with a
new one.
Extract the old battery and insert a new
battery in its place.
6
Reinstall the battery.
Reverse Steps 2 to 4 above to reinstall the
battery.
7
Check the UPS status.
1. Turn the machine power ON.
2. Press the ON button on the UPS operation
panel to check that the BATTERY LED is
OFF.
8
Write the battery replacement date.
Write the battery replacement date on the
UPS WARNING label (see "Safety instructions"
in this manual).
n
NOTE
See the manufacturer's instructions for detailed
operation of the UPS.
Replacing UPS internal battery
UPS unit
Lower right portion on
front of machine
Internal battery
Internal battery
side connector
UPS side battery
connector
Battery mounting fixture
Front panel
Front panel hook
Battery mounting fixture
mounting screw
Front panel
mounting screws
UPS operation panel
Step 2-6
4-6
4
Maintenance of options
3. Nozzle station
3.1 Checking and cleaning nozzle station sensor (1-year)
When the machine is equipped with the nozzle station (option), it is necessary to periodically check the nozzle
detection sensor status.
c
CAUTION
If the nozzle station sensor cannot detect the nozzle correctly, the nozzle change does not operate correctly or the
production cannot continue due to nozzle detection error.
e
1
Make the preparations for work.
1. Return all nozzles to the nozzle station.
2. To perform the work safely, put the
machine in the emergency stop state.
2
Open the shutter of the nozzle
station (hereafter referred to as
"ANC").
1. Open the [Unit] - [Head] tab.
2. Press the [Nozzle Stn Shutter] button to
open the ANC shutter.
54400-KMG-00
3
Open the Utilities mode.
1. Press the [Utilities] button on the left of
the screen.
2. The "Login" screen will appear. Check
that "Operator" is shown in the “User”
field, and then press the [OK] button.
54401-KMG-00
n
NOTE
When logging-in to the Utilities mode with "User:
Operator", the machine set values cannot be changed
or saved.
4
Select [ANC Auto].
Press the [024 ANC Auto] button.
54402-KMG-00
Step 3
[Utilities] button
Opening the Utilities mode
Select [OK] with "User: Operator".
Step 2
[Nozzle Stn Shutter] button
Opening the nozzle station shutter
Selecting [ANC Auto]
Step 4
Select [024 ANC Auto].