YSM10_Mainte_E.pdf - 第145页

A-2 Appendix 1.2 Power connection terminals When opening the front lower right panel, y ou can find the power connection terminals. Connect the power cable leads as shown below to the L1, L2, L3 and ground terminal (PE) …

100%1 / 153
A-1
Appendix
1. Specifications
1.1 Air regulator unit
The air regulator unit of this machine is in the inside of the panel on the lower left of the front of the machine.
Supply air
connecting parti
Air valve for tape cutter
Air pressure regulator and pressure gauge
Air supply/exhaust switch
Air filter
Oil mist filter
Air pressure regulator
Digital pressure gauge
53A01-KMG-00
n
Supply air pressure
This is the pressure of the source air supplied to the machine. Before setting the air pressure with the air regulator, make
sure that this supply air pressure is in the following optimal range.
YSM10 : 0.45MPa to 0.70MPa
n
Digital pressure gauge
When within the normal range, the air pressure displays in green. When the air pressure is beyond the upper/lower limit
values, the air pressure displays in red and an error occurs.
n
Set pressure and air-down detection pressure
Set the following air pressures with the air pressure regulator on this machine.
Air pressure setting for machine : 0.40MPa (+/-0.01MPa)
Interlock set pressure : Lower limit 0.33MPa, Upper limit 0.45MPa
n
Air supply/shutoff switch (valve)
Turning this switch to the right (EXH) shuts off air supply and exhausts air that remains inside the machine.
n
Source air connector
Connect the supply air to the entrance of the air filter. Prepare an air hose with an inner diameter of at least 8mm having
a 40SH socket (Nitto Koki, or equivalent), and connect it to this connector. Use dry, clean air passed through an air filter.
A-2
Appendix
1.2 Power connection terminals
When opening the front lower right panel, you can find the power connection terminals. Connect the power
cable leads as shown below to the L1, L2, L3 and ground terminal (PE) on the power terminal block.
n
Power supply specifications
Model name Power Frequency Power capacity
YSM10
3-phase AC 200/208/220/240/380/400/416V (+/-10%)
50/60Hz 7.0kVA
Power input terminals (L1, L2, L3)
Ground terminal (PE)
Main breaker
Power input terminals
53A02-KMG-00
Ring-tongue crimp terminal
Insulated crimp terminal
Power cable
L2
L1
L3
L=100
PE
53A03-KMG-00
c
CAUTION
Use a power cable whose conductor cross-section area is greater than 4mm
2
.
w
WARNING
TO AVOID THE RISK OF ELECTRICAL SHOCK, MAKE SURE THAT THE POWER SOURCE IS OFF BEFORE CONNECTING THE
POWER CABLE. ALSO MAKE SURE THAT THE GROUND CABLE IS SECURELY CONNECTED TO THE MACHINE.
A-3
Appendix
1.3 Connection between machines
To exchange signals such as board request and operation status with the downstream or upstream machine, the
"NEXT INTERFACE" and "PREVIOUS INTERFACE" connectors located on the rear of the machine are used. The
"NEXT INTERFACE" connector connects to the downstream machine, and the "PREVIOUS INTERFACE"
connector connects to the upstream machine such as a loader.
1.3.1 PREVIOUS INTERFACE connector
When the following three conditions are met, the PREVIOUS INTERFACE circuit in the machine allows the next
board to be carried in. (ADVANCED GATE is selected.)
1. Machine is ready for carrying in a board (BUSY OUT : ON)
2. Board carry-in signal is input from the upstream machine. (BA IN [N0100421] : ON)
3. Automatic operation signal is input from the upstream machine. (UR IN [N0100422] : ON)
n
NOTE
When the automatic operation signal (UR IN) of the upstream machine turns off during transfer of a board, the
machine temporarily stops carrying in the board.
When the board being carried in is detected by the entrance sensor of the machine, the BUSY OUT signal turns off.
Carrying in the board is finished when both the BUSY OUT and BA IN turn off.
7
12
4
8
1
14
11
3
PREVIOUS INTERFACE circuit
Upstream machine
PREVIOUS INTERFACE
connector
AMP 206043-1
(14-pin receptacle)
Signal input during
board carry-in
Signal output to
request board carry-out
Signal output during
automatic operation
Signal input during
automatic operation
Signal input during
waiting for board
between machines
1
2
3
4
5
6
7
8
9
10
11
12
13
14
BUSY OUT
(T01000E4)
+24V
+24V
LR OUT
(T01000E7)
UR IN
(N0100422)
BA IN
(N0100421)
LE OUT
(T01000F3)
I/O BOARD
This machine PREVIOUS INTERFACE
53A04-KMG-00
n
Board transfer signal specifications (PREVIOUS INTERFACE)
Pin No. Signal name Address I/O specifications Signal specifications
1 BUSY OUT T01000E4 Relay contact (zero voltage) output
Signal output during board
carry-in
2 BUSY OUT T01000E4 Relay contact (zero voltage) output
3 +24V Input common (+24V)
Signal input of board carry-
out request
4 BA IN N0100421 Voltage input
5 NC (with dummy pins) (Prevents misinsertion.)
6 to 8 NC
9 +24V Input common (+24V)
Signal input during
automatic operation
10 UR IN N0100422 Voltage input
11 LR OUT T01000E7 Relay contact (zero voltage) output
Signal output during
automatic operation
12 LR OUT T01000E7 Relay contact (zero voltage) output
13 LE OUT T01000F3 Non-voltage output
Signal output during
waiting for board between
machines
14 LE OUT T01000F3 Non voltage output