YSM10_Mainte_E.pdf - 第95页

3-28 3 Periodic maintenance items 6 Detach the control box filter . The filter mounting screws can be loosen manually. Loosen the filter mounting screws and detach the filter from the control box. 53358-KMG-00 n NOTE Mul…

100%1 / 153
3-27
3
Periodic maintenance items
4.2 Base
4.2.1 Cleaning the Control box filter
The air intake fan and the filter are in the control box that controls the machine. The filter should be cleaned
once a 6-month, although this may vary depending on the machine condition.
1
Power off the machine.
2
Turn off the air supply.
Turn the air supply/exhaust switch on the
lower left of the machine to the exhaust side
and turn off the main air.
3
Detach the tape cutter safety cover.
1. Remove the mounting screws of the tape
cutter safety cover with a phillips
screwdriver.
2. Pull the tape cutter cover forward to
detach it.
53356-KMG-00
n
NOTE
The interlock key is attached on the tape cutter safety
cover.
4
Detach the inner cover
1. Remove the mounting screws of the inner
cover with a phillips screwdriver.
2. Detach the cover.
3. A ground wire is connected to the rear
side of the cover. Remove the screw
mounting the ground wire with a phillips
screwdriver.
53357-KMG-00
n
NOTE
Toothed washer is attached to the ground wire mounting
screw. Make sure not to lose it when removing screws.
5
Clean around the control box.
If dust is found around the control box, clean
the area with a vacuum cleaner, etc. before
detaching the filter.
Step 3
Detaching the tape cutter safety cover
Tape cutter safety cover
Cover mounting screw
Bottom of cover
Interlock key
Step 4
Detaching the cover
Cover
Cover mounting screw
Control box
Ground wire
3-28
3
Periodic maintenance items
6
Detach the control box filter.
The filter mounting screws can be loosen
manually. Loosen the filter mounting screws
and detach the filter from the control box.
53358-KMG-00
n
NOTE
Multiple cables are connected to the control box. If it is
difficult to access to the filter, disconnect the cables
from the control box as necessary.
7
Clean the filter.
The filter locates between 2 covers. Detach
the filter and clean the dust sticking to the
filter with a vacuum cleaner or a vacuum
tool.
NOTE
If contaminants cannot be removed completely or if
the filter itself deteriorates, it is necessary to replace the
filter with a new one
8
Return the filter to the original
position.
Reattach the filter to the control box by
reversing its removal procedure.
9
Return the covers to the original
positions.
1. Reattach the inner cover.
2. Reattach the tape cutter safety cover.
c
CAUTION
Make sure not to catch cables when attaching covers.
Step 6-7
Detaching control box filter
Control box
Filter
Filter mounting screws
3-29
3
Periodic maintenance items
5. One-year inspection
This section describes the maintenance work performed once every year.
5.1. Head unit
5.1.1 Cleaning the spline shaft
As a general guide, clean the spline shaft once ever year, although this may vary depending on the machine
condition or surrounding situation.
n
NOTE
The procedure of HM head unit is described as example. The procedure of HM5 head unit is also the same.
1
(With the nozzle station) Return all
nozzles to the nozzle station.
1. Press the [Nozzle Change] button on the
[Unit] - [Head] tab screen.
2. Select "ALL" from the "Head Number" and
select "Store Nozzle" from the "Nozzle
Type" on the "Nozzle Change" screen.
3. Press the [OK] button to return all nozzles
to the nozzle station.
54305-KMG-00
n
NOTE
If the machine is not equipped with the nozzle station,
press the emergency stop button to open the machine
sefety cover and detach the nozzles manually.
2
Move the head unit.
e
1. Press the emergency stop button to open
the machine safety cover.
2. Move the head unit forward.
3
Remove the air hose and the
maintenance bolt.
1. Remove the maintenance bolt with a
slotted screwdriver or a wrench.
2. Disconnect the air hose from the air
connector.
53339-KMG-00
4
Mount the Z-axis at the work position.
As shown in the figure on the right, move the
shaft to a position where the Z-axis linear
scale is hidden. Insert the hex wrench into
the Z-axis mounting hole to mount the Z-axis.
53340-KMG-00
n
NOTE
A hex wrench may not be inserted smoothly as cables
are around the head. In this case, use a wire (less than
ø2.5 mm), etc. to mount the Z-axis.
Step1
[Nozzle Change] button
Returning all nozzles to nozzle station
Step 3
Removing air hose and maintenance bolt
Maintenance bolt
Air hose
Air connector
Step 4
ø2.5 mm
Mounting the Z-axis
Hex wrench