YS12调整.pdf - 第18页
Service Engineer Service I nformati on SI080 4004 E-000 = YS12 , YG12: Procedure for adjustmen t after installa tion of the mach ine 18/60 4.5.2. How to adjust the “b rightness “of t he scan camera The m ain cam era and …

Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
17/60
Note:
As the maximum value of the Bit value is the warning value for the upper limit, the adjustment can
be performed even when the value exceeds the Bit value.
If the Bit value exceeds 16128 (the seven eighth of the maximum value), it may attribute to the
deterioration of the lighting device. It is recommended to replace the lighting.
(The maximum value of the Bit value: 19400)
As the target value varies depends on the tools used for brightness adjustment, please follow the
specification of the machine.
* If the machine is not equipped with the sub fiducial camera (Option), this is the end of the
brightness adjustment.
9. Switch the fiducial camera. (Option: If the machine is equipped with two fiducial cameras.)
After completing the adjustment of the reference camera (the one on the right), perform
adjustment of the sub fiducial camera (the one on the left).
1) Click on the [Switch Camera] button on the “Fiducial Camera” screen to move the sub
camera to above the adjustment tool that is being caught by the reference fiducial
camera.
Figure 19
2) After the sub fiducial camera is moved, the camera number item on the “Fiducial camera”
screen changes from “Digital 1” to “Digital 2” automatically.
Figure 20
3) Check the number of the camera, and perform brightness adjustment.
Check if the values in the “Target” and “Bit” fields fall within the specification, and save
the data.
If the values fall within the specification, please fill in the values on the check sheet.

Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
18/60
4.5.2. How to adjust the “brightness “of the scan camera
The main camera and the side view camera of the scan cameras of YS series need to be adjusted
separately.
Please make sure to use the specified adjustment tool for the scan camera when performing
adjustment of the main camera in order to avoid the interference with the scan unit.
No tools (for brightness adjustment) are required for brightness adjustment of the side view
camera.
[Required tool]
Part No. Part Name Size Feature
KHW-M8806-D0* LIGHT ADJ.4 ASSY
11mm
square
Light gray + white
Table 11
1. Change the nozzle to “Nozzle 303A”.
Change the nozzle of Head 1 to “Nozzle 303A (314A)” in order to pick up the tool for brightness
adjustment of the scan camera.
If the machine is not equipped with the nozzle station, please press the [Emergency stop]
button and replace the nozzle by hand.
2. Select “Lightness” from the “Main Camera” item.
Click on the [Scan Camera] button on the main menu of the CalibSm.
Select “Lightness” from the “Main Camera” item.
Figure 21
3. Pick up the tool for brightness adjustment.
Use the [Vacuum ON/OFF] button.
If you click on the [Vacuum ON/OFF] button, Head 1 becomes able to pick up the tool for
brightness adjustment. Press the [Emergency Stop] button and make the nozzle vacuum
the tool with the light gray side facing down.

Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
19/60
Use the [Pickup From Tool] button.
(* “Pickup From Tool” function is currently under development.)
Please make sure to set the station for placing the components
when using the [Pickup
from Tool] button.
4. Start adjustment.
Click on the [Execute] button to display the following dialog box.
Figure 22
Check if the tool is set properly and click on the [OK] button to start adjustment.
5. Save the adjustment data.
When the adjustment is completed, the dialog box appears asking you to save the data.
Check if the values in the “Target” and “Bit” fields fall within the specification, and save the
data.
If the values fall within the specification, please fill in the values on the check sheet.
Figure 23
[Specification]
Color of the tool Tolerance of the measured value
Bit value
Main Light gray 100+-2 128 - 448
Table 12
Note:
If the Bit value does not fall within the specification, please check if the lens of the camera is clean,
if the lighting condition is good, or if the connector is connected properly.
Note:
As the maximum value of the Bit value is the warning value for the upper limit, the adjustment can
be performed even when the value exceeds the specification.
If the Bit value exceeds 448 (the seven eighth of the maximum value), it may attribute to the
deterioration of the lighting device. It is recommended to replace the lighting.
(The maximum value of the Bit value: 512)