YS12调整.pdf - 第5页

Service Engineer Service I nformati on SI080 4004 E-000 = YS12 , YG12: Procedure for adjustmen t after installa tion of the mach ine 5/60 2.5. Ot her required tools Some tools (nozzle) for adjustm ent may not come with t…

100%1 / 60
Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
4/60
< ACP Glass board> < AMF Glass board>
Figure 2
2.3. Component for mounting adjustment
Component Part No. Part Name
1005 Ceramic chip (reel) KGA-M880C-10* REEL CERAMIC 1005
Table 3
2.4. Tools used for multi camera adjustment (Option)
Adjustment using the QFP68 pin and FAMF station needs to be performed in addition to the ACP
adjustment using the 1005 chip components.
FAMF Station
(240*170)
KGA-M88F0-A0X
FAMF STATION
ASSY.
Glass QFP68
Pin
KW8-M880A-10X
GLASS QFP 68P
Board data FAMF_QFP68_ST_H48.ygx
Table 4
Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
5/60
2.5. Other required tools
Some tools (nozzle) for adjustment may not come with the machine depending on the
specifications of the customer’s machine. Also, some basic adjustment may need to be performed
depends on the adjustment result.
The following tools are required for those adjustments.
Type
303A/314A
nozzle
(For SOP)
KHY-M7740-A0X
NOZZLE
303A/314A
AS
It needs to
be prepared
if the
machine is
not
equipped
with ANC
and the
nozzle is not
purchased.
Type
304A/315A
nozzle
(For QFP)
KHY-M7750-A0X
NOZZLE
304A/315A
AS.
It needs to
be prepared
if the
machine is
equipped
with the
multi
camera and
the nozzle is
not
purchased
4mm square
nozzle for
adjustment
KHN-M88N1-00X
JIG,
NOZZLE R
Used for
checking
the head
angle
Glass
QFP16 Pin
(With a
white sticker
on the back)
KHY-M880A-00X
GLASS
QFP 16
ASSY
Glass QFP
for adjusting
the scale
of the scan
camera
Jig used for
checking
the pick up
position of
the feeder
Under
development
FEEDER
JIG ASSY.
For YS12
Jig used for
checking
the pick up
position of
the feeder
KM8-M34E0-B1X*
FEEDER
JIG ASSY.
For YG12
Table 5
Service Engineer
Service Information
SI0804004E-000 = YS12, YG12: Procedure for adjustment after installation of the machine
6/60
3. The flow of the adjustment
<The basic flow of the “Preparation for the mounting adjustment” after installing the
machine>
Figure 3
Installation of the machine
System data backup
Y-Axis dual drive
Offset adjustment
Adjust
“Orthogonalization level”
Check the parallelism
and the width of the
conveyor
Adjust the brightness of
each camera
Move on to
“Mounting Adjustment”
NG
Fiducial Camera
Relative Pos (Option)
Safety check
Check the status
and take measures
Turn on the machine
Measure the height of
the board surface