Cognex_Scanner_HS-60_HF_X-_D_S_F - CS_06.pdf - 第30页
2 Assembly instructions Special des ign Cognex Scanner SIPLACE HS-60 / HF-ser ies / X-series / D-series / S / F 10/2008 Edition 30 2.4 Scope of delivery General: 2 – Dataman I/O Box f rom Cognex (item no .: 001761 18-xx)…
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
10/2008 Edition
29
2 Assembly instructions
Special design Cognex Scanner
SIPLACE HS-60 / HF-series / X-series
/ D-series / S / F
2.1 Functional principle
The Cognex scanner enables to scan the 1D / 2D barcode on the PCB and sends it to the con-
veyor control unit for evaluation. 2
2.2 Requirements
For SIPLACE HS-50: 2
Mounting set for PCB barcode scanner HS-60 (Item no.: 00119330-01) 2
For SIPLACE HS-60 / D1 / D2 / D4: 2
Mounting set for PCB barcode scanner HS-60 (Item no.: 00119430-01) 2
For SIPLACE HF-series / X-series / D3: 2
Mounting set for PCB barcode scanner HF (Item no.: 00119648-01) 2
For SIPLACE S / F: 2
Mounting set for PCB barcode scanner S / F (Item no.: 00118530-01) 2
2.3 Restrictions
– The PCB barcode has to be placed on the first 15-22 cm of the PCB. The maximum scanning
range is arround 22 cm depending on the set scanning frequency.
– The barcode should have the same size.
– The exposure time has to be set up by the operator software of the scanner.
– The upper barcode has to be placed at least 3 mm from the side edge of the PCB.
– The lower barcode has to be placed at least 5 mm from the side edge of the PCB.
– Only the barcode on one side can be scanned at once.
– The common restrictions for PCB barcodes at SIPLACE machines still apply.
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
10/2008 Edition
30
2.4 Scope of delivery
General: 2
– Dataman I/O Box from Cognex (item no.: 00176118-xx)
– Adapter cable for Dataman 100 I/O Box (item no.: 00176120-xx)
– Assembly instructions for Cognex Scanner (item no.: 00195610-xx)
2
For one scanner: 2
– 1 Cognex scanner Dataman 100 (item no.: 00176117-xx)
– 1 Interface cable for Dataman 100 (item no.: 03062979-xx)
– 1 Holding bracket for scanner – upper side – premounted
or
1 holding bracket for scanner – lower side – premounted
– 2 Hexagon socket screws M3 x 5 mm
– 2 Washers ø 7,0 mm
2
For two scanners: 2
– 2 Cognex scanner Dataman 100 (item no.: 00176117-xx)
– 2 Interface cables for Dataman 100 (item no.: 03062979-xx)
– 1 (2) Holding bracket(s) for scanner – upper side – premounted
or
1 (2) holding bracket for scanner – lower side – premounted
– 4 Hexagon socket screws M3 x 5 mm
– 4 Washers ø 7,0 mm
2
For four scanners: 2
– 4 Cognex scanner Dataman 100 (item no.: 00176117-xx)
– 4 Interface cables for Dataman 100 (item no.: 03062979-xx)
– 2 Holding bracket(s) for scanner – upper side – premounted
or
2 holding bracket for scanner – lower side – premounted
– 8 Hexagon socket screws M3 x 5 mm
– 8 Washers ø 7,0 mm

2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
10/2008 Edition
31
2
2.5 Necessary tools
– Set of hexagon socket spanners
– Set of screw drivers
– Cable ties
– Cable clips
– Side cutter
– Measuring tape
– Lintfree cloths
– Ethylalcohol for cleaning
2
2
2
Interface cable for Dataman 100