Cognex_Scanner_HS-60_HF_X-_D_S_F - CS_06.pdf - 第30页

2 Assembly instructions Special des ign Cognex Scanner SIPLACE HS-60 / HF-ser ies / X-series / D-series / S / F 10/2008 Edition 30 2.4 Scope of delivery General: 2 – Dataman I/O Box f rom Cognex (item no .: 001761 18-xx)…

100%1 / 54
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
10/2008 Edition
29
2 Assembly instructions
Special design Cognex Scanner
SIPLACE HS-60 / HF-series / X-series
/ D-series / S / F
2.1 Functional principle
The Cognex scanner enables to scan the 1D / 2D barcode on the PCB and sends it to the con-
veyor control unit for evaluation. 2
2.2 Requirements
For SIPLACE HS-50: 2
Mounting set for PCB barcode scanner HS-60 (Item no.: 00119330-01) 2
For SIPLACE HS-60 / D1 / D2 / D4: 2
Mounting set for PCB barcode scanner HS-60 (Item no.: 00119430-01) 2
For SIPLACE HF-series / X-series / D3: 2
Mounting set for PCB barcode scanner HF (Item no.: 00119648-01) 2
For SIPLACE S / F: 2
Mounting set for PCB barcode scanner S / F (Item no.: 00118530-01) 2
2.3 Restrictions
The PCB barcode has to be placed on the first 15-22 cm of the PCB. The maximum scanning
range is arround 22 cm depending on the set scanning frequency.
The barcode should have the same size.
The exposure time has to be set up by the operator software of the scanner.
The upper barcode has to be placed at least 3 mm from the side edge of the PCB.
The lower barcode has to be placed at least 5 mm from the side edge of the PCB.
Only the barcode on one side can be scanned at once.
The common restrictions for PCB barcodes at SIPLACE machines still apply.
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
10/2008 Edition
30
2.4 Scope of delivery
General: 2
Dataman I/O Box from Cognex (item no.: 00176118-xx)
Adapter cable for Dataman 100 I/O Box (item no.: 00176120-xx)
Assembly instructions for Cognex Scanner (item no.: 00195610-xx)
2
For one scanner: 2
1 Cognex scanner Dataman 100 (item no.: 00176117-xx)
1 Interface cable for Dataman 100 (item no.: 03062979-xx)
1 Holding bracket for scanner – upper side – premounted
or
1 holding bracket for scanner – lower side – premounted
2 Hexagon socket screws M3 x 5 mm
2 Washers ø 7,0 mm
2
For two scanners: 2
2 Cognex scanner Dataman 100 (item no.: 00176117-xx)
2 Interface cables for Dataman 100 (item no.: 03062979-xx)
1 (2) Holding bracket(s) for scanner – upper side – premounted
or
1 (2) holding bracket for scanner – lower side – premounted
4 Hexagon socket screws M3 x 5 mm
4 Washers ø 7,0 mm
2
For four scanners: 2
4 Cognex scanner Dataman 100 (item no.: 00176117-xx)
4 Interface cables for Dataman 100 (item no.: 03062979-xx)
2 Holding bracket(s) for scanner – upper side – premounted
or
2 holding bracket for scanner – lower side – premounted
8 Hexagon socket screws M3 x 5 mm
8 Washers ø 7,0 mm
2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
10/2008 Edition
31
2
2.5 Necessary tools
Set of hexagon socket spanners
Set of screw drivers
Cable ties
Cable clips
Side cutter
Measuring tape
Lintfree cloths
Ethylalcohol for cleaning
2
2
2
Interface cable for Dataman 100