Cognex_Scanner_HS-60_HF_X-_D_S_F - CS_06.pdf - 第38页
2 Assembly instructions Special des ign Cognex Scanner SIPLACE HS-60 / HF-ser ies / X-series / D-series / S / F 10/2008 Edition 38 : Fix the interface cable with cab le clip and cable tie. 2 2 2 Cognex scanner upper cabl…

2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
10/2008 Edition
37
: Connect the interface cable with the barcode manifold X1 to X4.
: Switch the switch S1 number 1 to 4 (depending on the position of the connected scanners) to
OFF.
2
The unconnected ports has to stay ON. 2
2
2
2
2
2
2
2
2
2
2
Interface cable
Switch S1

2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
10/2008 Edition
38
: Fix the interface cable with cable clip and cable tie.
2
2
2
Cognex scanner
upper cable
Cognex scanner
lower cable
Cable clip
and
cable tie
Interface cables for
Dataman 100

2 Assembly instructions Special design Cognex Scanner SIPLACE HS-60 / HF-series / X-series / D-series / S / F
10/2008 Edition
39
2.8 Setup of the Cognex scanner
: Shut down the machine and switch it off at the main switch.
: Disconnect the interface cable from the relevant scanner and from the barcode manifold.
2
If the adapter cable is connect directly to the interface cable, the scanner can be damaged.2
2
2
2
Adapter cable for
Dataman I/O-box
Dataman I/O-Box
Connection to
barcode manifold