FlexSeam Dispensing System Customer Product Manual.pdf - 第23页
Flexseam Dispensing System 19 Part 1127900_01 E 2019 Nordson Corporation Install the Applicator on the Robot See Figure 6 for the Flexseam applicators. Use the mounting block and screws supplied with the applicator to in…

Flexseam Dispensing System
18
Part 1127900_01
E 2019 Nordson Corporation
Ship‐With Kit Contents
P/N 983403
P/N 7407652
P/N 7402541
P/N 7402601
P/N 1003505
P/N 982166
P/N 983402
1
2
3
4
5
6
7
8
P/N 982023
P/N 983067
9
P/N 983400
10
P/N 1005078
11
Figure 5 Contents of the ship‐with kit
1. 7407652 CHECK VALVE, SYRINGE,
ASSY, PJ300
2. 7402541 CORDSET, SOL, PJ, UNITY
TOUCH
3. 7402601 SCR SKT M2X5, ZN
4. 1003505 SCR, SKT, M4X8, SST
5. 983402 WASHER, FLT, M,
NARROW, M4, STL, ZN
6. 983403 WASHER, LK, M, SPT,
M4, STL, ZN
7. 982166 SCR, SKT, M5X16, BL
8. 982023 SCR, SKT, M3X8, BL
9. 983067 WASHER, FLT, M,
REG, M3, ZINC PLATE
10. 983400 WASHER, LK, M,
SPT, M3, STL, ZN
11. 1005078 TUBING, PTFE 6
MM OD X 1MM WALL
(0.26FT)

Flexseam Dispensing System
19
Part 1127900_01
E 2019 Nordson Corporation
Install the Applicator on the Robot
See Figure 6 for the Flexseam applicators. Use the mounting block and
screws supplied with the applicator to install the applicator on the robot.
Figure 6 Installing a Flexseam applicator on a robot

Flexseam Dispensing System
20
Part 1127900_01
E 2019 Nordson Corporation
Make the Air Supply Connections
Using items from the ship‐with kit as needed, make the air supply
connections shown in Table 3 and Figure 7. The air supply must be clean,
dry, regulated, un‐lubricated compressed air. Set the operating air pressure
to max 8 bar (116 psi).
Table 3 Air Supply Connections
Item No. in
Fig. 7
Pneumatic Connection Connect to... Then connect to...
1 Main air supply input Main air supply Air regulator input port
2 Air supply to applicator
solenoid valve
Air pressure regulator output
(Y‐fitting)
Air input port on applicator
solenoid valve
3 Air supply to controller
through air dryer
Air pressure regulator output
(Y‐fitting)
Air dryer input/output ports
and controller air input port
4 Air supply to applicator
adhesive syringe or end cap
Air output port on top of
controller
Air fitting on top of
applicator adhesive syringe
or end cap