22 JAKA Zu Se
cable with interfaces matching the cable interface on the sensor. Align and push the multi-core cable
interface with the sensor cable interface as shown below. After being pushed in, the threaded
connection shell from the multi-core cable interface shall be tightened to avoid looseness of the cable,
so as to achieve the performance of IP64. It shall be noted that during installation, the wiring of each
cable core is operated strictly according to the color definition of the given core. If the positive and
negative poles of the power supply are connected in reverse, the sensor will be damaged. Please be
careful!
Cable Connection Operation
No.
Definition
1
Power supply+
2
Power supply
3
Bus 422 sensor receiving
terminal +
4
Bus 422 sensor receiving
terminal -
5
422 or 485 bus sensor
sending terminal +
6
422 or 485 bus sensor
sending terminal -
7
422/485-USB Wiring Diagram of Converter and Power Plug
JAKA Zu Se 23
1.3 Basic Sensor Parameters
Fx/Fy (N)
200
Fz (N)
200
Mx/My (Nm)
8
Mz (Nm)
8
Overload level
(%)
300
Accuracy (%)
0.5
Precision (%)
0.1
Protective class
IP64
Operating
temperature (°C)
5~80
Power supply
voltage (V)
9~24
Communication
Interface
RS422
Sampling
Resolution (Bit)
24
Precision: Precision is the evaluation index symbolizing the extent of consistency between multiple
measured values, that is, the output curve consistency degree obtained by the sensor when the
input is tested for multiple times in a unified direction. The precision of reproducibility is the
percentage of the standard deviation of the output error to the rated output (%FS).
Accuracy: Accuracy is the evaluation index of the deviation degree between the measured value and the
true value. The accuracy is the percentage of the standard deviation of the deviation between
the output and the theoretical truth value and the rated output (%FS)
1.4 Precautions for Use
a. Do not use in an environment with temperature and humidity outside the allowed range of
specifications.
b. The wiring must be completely correct. When the power is turned on, please check whether the
color of the connection cable is correct in accordance with the manual. If an error occurs at the connection
terminal, the internal circuit of the sensor may be short cut and possibly be damaged. Please be sure to
check.
c. The sensor has an embedded system and other precision parts. our company has carried out
relevant vibration and impact tests, but please pay attention to the product drop, excessive vibration will
lead to malfunction.
d. Do not knock when installing the sensor. Especially when it is matched with the adaptor plate, if the
clearance fit is tight due to the adaptor plate processing and other factors, do not knock the sensor,
otherwise it will cause damage to the sensor performance.
After the sensor is installed and powered on, it is recommended to preheat it for an hour before
operation.
In the actual use of the sensor, the quality of the mounted equipment shall be taken into consideration
to avoid overloading.
24 JAKA Zu Se
If there is any doubt or failure during use, please do not try to operate without permission and directly
contacting our Company.