2OM-1751-003w_G5S.pdf - 第159页

2OM-1751 2-37 1303-001 (D01_02) PCB Finishing Position The PCB Finishing Position is selected in this text box. Output The component placement is performed on the downstream side. Note For the PCB with the size of 260 mm…

100%1 / 380
2OM-1751
2-361303-001
3.4 Control
(D01)
Control Data
When the [Control] tab is pressed in the "Control" window, the following tab
sheet appears.
F2B30
(D01_01)
Placement Mode
"Product" or "Pass" is selected for the placement mode in this pane.
Normally, "Product" is selected.
Product
: When selected, the placement operation is performed.
Pass
: When selected, the PCB is passed without placement.
Note
When the pattern program set to "Pass", is setup on the Pattern Program
Data, the vacuum pump is automatically turned OFF.
Graphic
Development
3.4 Control
2OM-1751
2-371303-001
(D01_02)
PCB Finishing Position
The PCB Finishing Position is selected in this text box.
Output
The component placement is performed on the downstream side.
Note
For the PCB with the size of 260 mm or more in the X-direction, the
components are to be placed in the downstream side.
Process Position
F2B31
Input
The component placement is performed on the upstream side.
Process Position
F2B32
Sequential
The component placement is performed on the upstream and downstream
sides successively.
Process Position
F2B33
3.4 Control
2OM-1751
2-381303-001
(D01_03)
Pre-PL cmpnt thkns
PCB Top [mm]
When some components are placed previously on a PCB by the input
machine, etc., and transferred to the main machine, be sure to enter the
thickness of the tallest component of all in the text box.
Tallest Previously Placed Component
Set this thickness in the text box.
PCB
F2B34
Data Input Range
0 to 25.400
Notice
(a) When components are placed previously and the main machine
is operated with "0.00" in this text box, some of the previously
placed components may interfere with components to be
placed newly.
(b) It is advisable that placement data should be created such that
shorter components are placed before the tallest one.
(c) When the specied thickness of a previously placed component
differs from the actual one, the light emitter of the Side View
Camera may interfere with the previously placed component.
2.0 mm
4.0 mm
2.0 mm
3.0 mm
2.0 mm
NL Origin Position NL Origin Position
Light
Emitter
Light
Emitter
Previously
Placed
Component
PCB
Placement Level
No Previously Placed Component Previously Placed Component
F2B35
3.4 Control