2OM-1751-003w_G5S.pdf - 第233页
2OM-1751 4-19 1303-001 2.4 "Handling/Plac." T ab Sheet *D:component recognition Shown is the number of components judged "NG" (No Good) through recognition process. *E:component thickness Shown is the…

2OM-1751
4-181303-001
2.4 "Handling/Plac." Tab Sheet
When the [Handling/Plac.] tab is pressed in the "MNG.DT." window, the
following tab sheet appears inside the window.
[1]
[2]
[3]
"Handling/Plac." Tab Sheet F2D12
[1] Z:Total components
Shown is the number of component picks.
*A:component missing[sensor]
Shown is the number of component missing errors detected by the
component linear measure detection sensor.
(Case: "NG" (No Good) in Component Recognition and Linear Measure
Detection Sensor)
*B:component missing[recognition]
Shown is the number of component missing errors detected through
component recognition operation.
*C:component vertical[sensor]
Shown is the number of components judged "NG" (No Good) by the linear
measure detection sensor although they are judged "OK" through component
recognition process.
*G:component posture[recognition]
Shown is the number of reversed component and polarity judgment errors
detected in the recognition process.
*L:obverse/reverse[sensor]
The "judged front/rear error" times for each feeder, detected using the linear
measure, is displayed in these data boxes.
2.4 "Handling/Plac." Tab Sheet

2OM-1751
4-191303-001
2.4 "Handling/Plac." Tab Sheet
*D:component recognition
Shown is the number of components judged "NG" (No Good) through
recognition process.
*E:component thickness
Shown is the number of errors in compo
*F:pick-up difference
Shown is the number of components judged "NG" (No Good) through
recognition process.
*H:measurement error
Each text box shows the total count of measurement error in each individual
feeder.
*K:coplanarlty
The times of error decided in the coplanarity error detection is shown in this
data box.
The percentage of error detected in the optional device installation, is
displayed in this data box.
[2] Component chuck
[((*total comp.-(*A+*B+*C+*G+*L))/*Total comp.) × 100] (%)
The value (%) is determined by the following formula.# of Picks -
(Counts in "A" + Counts in "B" + Counts in "C"
+ Counts in "G" + Conuts in "L")
×100
# of Picks
[3] Component placement
[((*total comp.-(*A+*B+*C+*D+*E+*F+*G+*H+*K+*L))/*Total comp.)
× 100] (%)
The value (%) is determined by the following formula.
# of Picks - (Counts in "A" + Counts in "B" + Counts in "C"
+ Counts in "D"+ Counts in "E"+ Counts in "F"+ Counts in "G
+ Counts in "H"+ Counts in "K"
+ Conuts in "L"
)
×
100
# of Picks
Note
About Data Counting (Counting of "*A: component missing [sensor]"
and "*B: component missing [recognition]")
The machine stops in an error condition according to the number of times
(the number of continuous component missing errors to be counted to stop
the machine in an error condition) set in the "1" text box of "Error process"
in the "Control Data" tab sheet of a "Component Library" window.
In this case, the number of missing component errors is not added to the
number of picks and the number of chuck errors.

2OM-1751
4-201303-001
3. "CRNT.PP.MNG.DT" Window
This window enables the operator to conrm the production management data for
the current pattern program.
[2]
[1]
[3]
F2D13
[1] Tabs and Tab Sheets
There are three tab sheets for the "CRNT.PP.MNG.DT" window. When any
tab is pressed, the corresponding tab sheet appears.
Buttons Description
PP Prod. His.
In this tab sheet, the automatic operation starting date and time and
ending date and time are recorded.
Mach.Prfrm.
In this tab sheet, the device management result data is displayed.
Reference
Refer to "2.1 "Mach.Prfrm." Tab Sheet" for each item.
FdrMng.
In this tab sheet, the pick-up data for each feeder is displayed.
Reference
Refer to "2.2 "FdrMng." Tab Sheet" for each item.
T2D3
[2] [Clear] Button
When this button is pressed, all the data parameters are deleted in each tab
sheet for the "CRNT.PP.MNG.DT" window.
[3] Information on Tatalization File Information
The update date and time for the totalization le and pattern program are
displayed in this area.
Graphic
Development
3. "CRNT.PP.MNG.DT" Window