00194329-03.pdf - 第151页

Replacement instructions - Gantry c able and hose carrier SIPLACE HS / S / F 01/2007 Edition 151 : Separate the hoses Gantry 2 + 4: up to approx. 1 cm before the clamp Gantry 1 + 3: to a length of approx. 200 mm 2 : Atta…

100%1 / 198
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
150
: Gantry 2 + 4 only:
Now screw on the partition plate.
2
2
: Gantry 1 and 3:
Insert the hoses through the mount for the X/Y-axis distributor board.
: Cut the hoses connected to the left of the X-axis motor to the right length:
Gantry 1 and 3: 170 mm,
gantry 2 and 4: 245 mm.
2
Measure 245 mm from here
(gantry 2 and 4)
Measure 170 mm from here
(gantry 1 and 3)
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
151
: Separate the hoses
Gantry 2 + 4: up to approx. 1 cm before the clamp
Gantry 1 + 3: to a length of approx. 200 mm
2
: Attach the compressed air hoses to the Y-axis gantry as shown and press them on firmly.
When you attach the hose, there is a slight resistance that must be overcome before the hose
is seated correctly.
2
2
2
2
2
2
2
2
Compressed air hoses
No. 1 - 7 from right to left
Compressed air con-
nections
No. 1 - 7 from bottom to top
Connection 7
Hose 7
Connection 1
Hose 1
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
152
: Cut the hoses attached to the right of the X-axis motor to the correct length.
Measure from the Y-axis cable clamp (see photograph):
Gantry 1 and 3: 220 mm,
gantry 2 and 4: 250 mm.
2
2
: Separate the hoses up to approx. 1 cm before the clamp.
2
2
2
2
2
2
2
2
2
2
Measure from here