00194329-03.pdf - 第162页
Replacement instructions - Gantry c able and hose carrier SIPLACE HS / S / F 01/2007 Edition 162 : Remove the design pane ls and tighten the scre ws on the arched cross- piece once more. : Loosen the screws of the U-shap…

Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
161
These instructions apply to S and F machines from S-20 / F4 onwards.
Replacement of the cable and hose carrier is shown with reference to the SIPLACE S-27 HM. Re-
placement on the other types of machine is carried out in the same way. 2
2.2.9 Dismantling the cable and hose carrier
2
It is absolutely essential to remove the protective covers in order to replace the cable and hose
carrier. 2
2
: To remove the design panels, loosen the screws on the panels. To do this, loosen a screw on
each arched cross-piece on the output side.
2
Only loosen one screw on each cross-piece. The arched cross-piece is very heavy and might oth-
erwise fall off and cause damage or injury. 2
2
2
Screws
Screws on arched cross-piece.

Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
162
: Remove the design panels and tighten the screws on the arched cross-piece once more.
: Loosen the screws of the U-shaped profile to which the component table is attached, and re-
move the profile (see photograph on left).
Detach the grounding cable before removing the cover.
2
The cover is very heavy and should be placed carefully on the ground. 2
2
2
2
2
2
2
2
2
2
2
Remove the cover

Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
163
: Loosen the screws in the left-hand upright and remove it together with the swivel door.
2
: Loosen the screws on the Schmersal switches for the protective covers and carefully remove
the Schmersal switches.
2
2
Remove uprights with swivel door
Fixing plate for