Replacement instructions - Gantry c able and hose carrier SIPLACE HS / S / F 01/2007 Edition 194 : Cut the compressed air hoses to the correct length so that they can be inserted firmly in to the connectors and are not u…

100%1 / 198
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
193
: Run the hoses or pairs of hoses neatly together, and secure them with cable ties (see photo-
graph).
: Fasten the bundle of hoses together with one or two fixing clips.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
194
: Cut the compressed air hoses to the correct length so that they can be inserted firmly into the
connectors and are not under tension (see photograph).
: Attach the hoses in the following order:
2
2
2
2
2
2
2
2
2
1
3
7
65
4
F machine:
Connection 2
1
3
7
65
4
S machine:
free
4
Replacement instructions - Gantry cable and hose carrier SIPLACE HS / S / F
01/2007 Edition
195
: Run the ribbon cables neatly to the gantry conversion board.
Be careful not to damage the cables on sharp edges.
2
2
: Fix all ribbon cables and hoses with cable ties at suitable points so that they are unobstructed
at all points and cannot rub against anything.
: Fit the plate with the interface box.
: Move the gantry in the X and Y directions.
Check that the cable and hose carrier is fitted correctly.
2
: Fit the protective covers onto the placement machines.
: Screw on the stops for the protective covers (2 screws on each).
: Fix and align the Schmersal switches.
: Fit the stopper.
: Fit the uprights and swivel doors.
: Connect the grounding cable to the U-shaped profile and fit it to the placement machine.
: Screw on the design panels once more (loosen just one screw in each arched cross-piece).
Plug in all cables
Cable tray