TM1467_ReleaseNote_PSC乮Print Stability Control乯-SyringeType-Function.pdf - 第3页

   SMT Software Engineeri ng Group  IMOperationsYAMAHAMOTORCO. ,LTD.   MD OC-SOFT50033 3/30  And more, P SC function has follo wing functions.  T he func tion to warn t he solde r in syringe is empt y . …

100%1 / 30
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50033
2/30
1. Introduction
The target model and version are as follows.
Table1.1 Target model and target version
Item Object Remarks
Target model YS Series Printer (YSP)
Target version VGOS V3.10STD R1.000 or later
Y.FacT V1.10STD R1.000 or later
2. Summary
PSC Print Stability Control function is the function that the change of the solder rolling width on
the mask is suppressed within 1mm by scanning the rolling width and supplying the solder automatically,
and the print quality can be improved.
Fig.2.1.1 Purpose of PSC function
Mask
Solder
Rolling
Width
Board
PSC
Scanning the rolling width, Auto-supplying the solder
When the change of the rolling width is suppressed
within
the plus or minus 1mm, the solder filling amount is steady.
If the rolling width is unstable,
the solder filling amount to
board becomes unstable.
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50033
3/30
And more, PSC function has following functions.
The function to warn the solder in syringe is empty. Please refer to “4.2.1 Solder empty warning
function”.
The function to automatically initially supply the solder on the mask. Please refer to “4.2.3 Initial
solder supply function”.
The function to display the PSC action result transition graph while the Auto-running. Please refer
to “4.2.5 PSC action result output function”.
3. Settings
The settings used to this function are as follows.
3.1 Machine settings
3.1.1 Installation settings
In the window of [Machine] [Setting] [Machine Information] [Installation Setting], please set
the “Syringe Type” in “PSC (Print Stability Control)”. Refer to “Fig.3.1.1.1”.
NOTE: When this setting is changed, please save it and reboot the machine.
Fig.3.1.1.1 Installation setting
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50033
4/30
3.1.2 Supply mode
The PSC action has two supply modes. They are the “Interval” mode and the “Feedback” mode. The
“Interval” mode is the mode that supplies the specified time at the specified interval. The “Feedback”
mode is the mode that automatically calculates the supplying amount to keep a targeted rolling width.
The method of setting the supply mode is described in this section. For details of PSC action, please
refer to “4.1 Operation while the Auto-running and the Rolling”. For more detail parameters of this
function, please refer to “7.2 PSC setting”.
When you enable this function in “3.1.1 Installation Setting”, [PSC Setting] is added in [Setting]
[Machine Data].
Please select “Supply Mode” from “Interval” and “Feedback” in [PSC Setting] window.
Fig.3.1.2.1 PSC setting