TM1467_ReleaseNote_PSC乮Print Stability Control乯-SyringeType-Function.pdf - 第5页

   SMT Software Engineeri ng Group  IMOperationsYAMAHAMOTORCO. ,LTD.   MD OC-SOFT50033 5/30  3.2 B o ard data W hen you enable t his function , the [PSC] tab is appeared in [Print] window . Fig.3.2. 1 [Pr…

100%1 / 30
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50033
4/30
3.1.2 Supply mode
The PSC action has two supply modes. They are the “Interval” mode and the “Feedback” mode. The
“Interval” mode is the mode that supplies the specified time at the specified interval. The “Feedback”
mode is the mode that automatically calculates the supplying amount to keep a targeted rolling width.
The method of setting the supply mode is described in this section. For details of PSC action, please
refer to “4.1 Operation while the Auto-running and the Rolling”. For more detail parameters of this
function, please refer to “7.2 PSC setting”.
When you enable this function in “3.1.1 Installation Setting”, [PSC Setting] is added in [Setting]
[Machine Data].
Please select “Supply Mode” from “Interval” and “Feedback” in [PSC Setting] window.
Fig.3.1.2.1 PSC setting
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50033
5/30
3.2 Board data
When you enable this function, the [PSC] tab is appeared in [Print] window.
Fig.3.2.1 [Print] - [PSC] tab
Table3.2.2 Parameter of board data
Item Initial Input range Content
PSC (Print Stability Control) Not Use
Not Use / Use Please select the Not Use” or Use” of this
function in this board data.
Target Rolling Width (mm) 16.000
0.00099.999
Please specify the target rolling width.
NOTE: When “Interval” mode is selected, this
parameter is only used to calculate the supply
time in executing solder initial supply.
Solder Supply Interval (Board) 50
09999
This is the solder supply interval while the Auto-
running. The solder is supplied only in time
specified as the following "Solder Supply Timer
(msec)" after the board of the number of sheets
specified by this parameter is printed.
SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50033
6/30
NOTE: When “Feedback” mode is selected, this
parameter is hidden.
Solder Supply Timer (msec) 1500
099999
This is supply time in which solder is supplied at
once. The solder of about 10.0 (g) per 2000 (msec)
is supplied. (But, the solder supply amount
depends on the supply pressure, the kind of solder,
and the temperature.)
NOTE: When “Feedback” mode is selected, this
parameter is hidden.
Solder Supply Pressure (MPa) 0.150
0.0000.400
The supply pressure of the solder used by this
board data can be input. Please use it as a memo.
(This value is not used to control pressure.)
Solder Supply Offset (mm) 0.000
-999.999
999.999
This value changes the position in which solder is
supplied. When plus value is set, the supply
position is offset the direction that outward from
mask center.
NOTE: Please set an initial value usually.