3 Camera Calibration in SW 605.xx Stations 3.4 XML Report (SW 605.xx) Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020 63 Parameter name Value of camera Comme…

3 Camera Calibration in SW 605.xx Stations
3.4 XML Report (SW 605.xx)
62 Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020
Parameter name Value of camera Comment
<Firmware Firmware versions which are "downloadable"
with SITEST
Application ="0.5.03.02"
BIOS ="0.5.03.CF" />
- <Calibration
FirstCalibration ="22.5.2006" Calibration date during manufacture
LastCalibration ="2006-10-25" State of current –, last calibration.
TypeOfLastCalibration ="20" 1 Brightness calibration for production / 20 –
calibration in the application on site
NumberOfCalibrations ="2"> Counter status of all complete calibrations
(saved in the camera EPROM)
<CameraPosition Position of stationary camera in X/Y machine
coordinate system
x_mm ="0.000"
y_mm ="0.000"
Angle_degrees ="-90.00" /> Camera angle in the machine
<FocusHeight
z_mm ="14,833" />
<Illumination Brightness values of illumination levels after
white balance
Plane1 ="123" Camera-specific illumination levels
> Values should be similar
> Threshold values depend on the camera.
See table in section 3.5
Plane2 ="126"
Plane3 ="117"
Plane4 ="140"
Plane5 ="129"
Plane6 ="0" Levels with ‘0’ are not available for the respect-
ive camera type.
CameraGain ="2,925" Camera amplification factor
DeadTime ="48800" />
<Shading Status ="0"
ShadingFactorX0 ="0.000000"
ShadingFactorX1 ="0.000000"
ShadingFactorX2 ="0.000000"
ShadingFactorX3 ="0.000000"
ShadingFactorX4 ="0.000000" />
<DefaultScale
x_nm ="26683" Default pixel size from construction
y_nm ="26710" Default pixel size from construction
StateX ="2" />
<CurrentScale
x_nm ="26741" Measured pixel size
y_nm ="26772" /> Measured pixel size
</Calibration>
<Statistics
NumberOfFlashes ="0"
NumberOfBootUps ="262" />

3 Camera Calibration in SW 605.xx Stations
3.4 XML Report (SW 605.xx)
Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020 63
Parameter name Value of camera Comment
<Diagnostics
StateOfGSM ="4"
LastError ="00" />
<HardwareState
ChecksumEEPROM ="OK"
Selftest ="OK" />
- <SensorSpecificData
PixelScale ="124">
<FieldOfView
StartX ="204"
StartY ="8"
SizeX ="1220" No. of pixels (image points) per line in field of
vision
SizeY ="1220" /> No. of pixels (image points) per column in field
of vision
<Extended
MaxIllum ="10"
MinSleep ="10"
ModusTrigger ="4"
ModusTransmit ="0"
ModusEnable ="2"
ModusSense ="12"
ModusExposure ="5"
Can0ToPlane ="1"
Can1ToPlane ="2"
Can2ToPlane ="4"
Can3ToPlane ="8"
Can4ToPlane ="16"
Can5ToPlane ="32"
FlashDelay ="0"
FinishDelay ="0"
ModusFlash ="0"
TriggerExposure ="20"
MaxExposure ="200" />
</SensorSpecificData>
</Sensorsystem>

3 Camera Calibration in SW 605.xx Stations
3.4 XML Report (SW 605.xx)
64 Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020