4 Camera Calibration in Stations from SW705.03
4.7 Report File from SW 705.03 onwards
72 Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020
Fig.38: Checking the camera for soiling
ü The user level is Advanced production.
► Go to the Maintenance view.
► Select the Verification section.
► Click on the Check for camera soiling
button.
Fig.39: Checking the camera for soiling
ü The last result (if present) will be shown!
► Go to the Maintenance view.
► Select the camera to be measured.
► Place the contrast standard in the cali-
bration pocket and make sure that the con-
trast standard is correctly positioned.
► Click on the Check for camera soiling
button.
ð The result will be shown and can be
saved in a file on the station computer
with the Generate report function. This
same file is then saved via the LineDia-
gnostic software on the Siplace Pro
computer, in the MaintenanceReports
folder.
●
On the station computer: C:\Sirio\Work\MaintenanceReports
●
On the SIPLACE Pro computer: C:\MaintenanceReports
4.7 Report File from SW 705.03 onwards
NOTICE
From the above mentioned station software version onwards a report file will auto-
matically be generated after the calibration.
Example: Report_FCCS_SX2_00004133_2011-01-31_15-20-40 currently from
SW705-03.pdf
NOTICE
Example for a report file of a SIPLACE SX2 machine
The row numbers of the first table references the results of the relevant camera in the fol-
lowing tables.

4 Camera Calibration in Stations from SW705.03
4.7 Report File from SW 705.03 onwards
Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020 73
Fig.40: List of cameras
●
The list of cameras gives an overview
of the calibration states and the
proper storage of the calibration val-
ues.
Fig.41: Camera details and calibration history
●
The camera details show the mater-
ial number, the serial number and the
number of flashes, i.e. the number of
components that have been centered
optically.
●
The calibration history shows the
dates of the first and the last cali-
bration as well as the number of cali-
bration processes.

4 Camera Calibration in Stations from SW705.03
4.7 Report File from SW 705.03 onwards
74 Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020
Fig.42: Calibration results
●
Calibration results for each success-
fully calibrated camera.
●
The result column shows for each illu-
mination level the set illumination dur-
ation with respect to the white stand-
ard as reference and the camera
amplification (camera gain).
The evaluation of the results with re-
spect to threshold values depends on
the camera type. See also table in
section 3.5.
●
The difference column shows the de-
viation to the last calibration.
4.7.1 Report file from SW 712.xx
Excerpt from the report file:
●
The results list has been extended by
a column on the right, to show the
camera cleaning status.
●
The degree of soiling is given as a
percentage and the bars show the
soiling in 1/3 steps from green to yel-
low and red.
●
If the display is in the red area, you
urgently need to clean the camera or
replace it.