Station Software 707.1 SP2 / Version Description Ausgabe 11/2014 Edition
31
Fine adjustment of the pitch at the feeder
For feeder types < 12mm, the current pitch in the feeder has to be set to > 4mm to achieve the
same functionality as on the operator panel of the feeder and to avoid incorrect settings for smaller
pitches.
Fault-tolerant operation of the Twin Head
If Segment 1 has been deactivated or removed from the configuration, e.g. some single
placement positions might not be reachable because of the limited traveling range of Segment
2. The machine stops with a corresponding error message and the board cannot be finished.
No plausibility check will be performed in advance for a defined job or a board that enters the
machine.
Head calibration is not possible, if Segment 1 is deactivated or has been removed from the
configuration. If this is necessary, the functioning segment has to be installed on the position of
Segment 1.
No CAN communication with a segment that has been removed from the configuration.
No control of the Z-security for a segment that has been removed from the configuration.
A segment that has been removed from the configuration will not be actively secured, but will
generally be hold by the cylinder.The segment is held high enough, so that it will not come in
touch with placed components. If necessary, the nozzle has to be manually removed.
If a long/wide component is placed by the active segment, no check will be performed whether
a component is wiped off from the segment that has been removed from the configuration.
PCB barcode detection with Molex Traceability Pad
Barcode-controlled production is not supported.
Traceability is not possible until the barcode has been successfully read. Therefore, the
Traceability Pad should be placed / read in placement area 1 of the first placement machine in
the line. Only in this case, it is warranted that the Traceability information can be correctly
saved for all stations in the line.
Barcodes can only be reliably measured by SIPLACE Vision if the component height (without
board warpage) at the position of the Traceability-Pad is < 1,5mm.
When the placement position is taught, the barcode / fiducial position will not be moved
correspondingly.
C&P20 M placement head
Supported on the CA-series and SIPLACE X4 S micron / X4i S micron placement machines only.
C&P20 P placement head
Supported on the X-series S placement machines only.
Twin VHF placement head
Supported on the SX1/SX2 V2 placement machine only.
No fast gantry exchange possible.
Must not be used together with the VHF P&P placement head on a machine.
SIPLACE JTF-S
Supported on the SX1/SX2 V2 and SIPLACE X-series S placement machines only.
Station Software 707.1 SP2 / Version Description Ausgabe 11/2014 Edition
32
SIPLACE JTF-M
Supported on the SX1/SX2 V2, X4i S micron and SIPLACE X-series S placement machines
only.
On the SX1/SX2 V2 placement machine no tape feeder can be placed on the location beside
the JTF-M because no empty tape channel is available.
SIPLACE Wafer Systems
Supported on the CA-series placement machines only.
A specific table is required.
External virtual ink spot handling
Only possible for stations with station software from version 707.0 and SIPLACE Pro from
version 11.1.
Physical and virtual ink spots must not be mixed.
The board must not contain any active ink spots.
Software installation on older placement machines
During the station software installation on older X-series or X S-series placement machines that are
equipped with a CPP placement head and an MTC at location 2, a message is displayed that the
travel range has to be remeasured.
This occurs once to initialize the buffer monitoring. Thereafter, it will be checked if a retrofit has
been performed that requires a recalibration of the travel range.
CPP / Twin Head placement heads on SIPLACE CA series
Stationary cameras may be installed on location 1 and 3 only.
Twin Head may be installed on location 3 only.
The CPP placement head is only supported in the high position on SIPLACE Wafer Systems.
Compatible mode: trays teachen
Trays that are taught in compatible mode cannot be stored back to SIPLACE Pro.
Station Software 707.1 SP2 / Version Description Ausgabe 11/2014 Edition
33
10 Corrected Errors
10.1 707.1 SP2 Station Software
The 707.1 SP2 station software version contains all error corrections of the previous
701.xx 707.1 SP1 versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
eSW: Improvement of the communication between star- and z-axis.
D1-101366602
D17077-6301
During machine update the I/O Module could not be reached.
D1-101855901 The station was searching for a nozzle changer on location 2 during booting.
D1-101902301 Error message 30608 Measured nozzle length too long for
nozzle of type 2820
.
D1-101916701 eSW: after having returned and picked up the nozzles, the "32581 Machine
has stopped: cannot close nozzle changer" error message was displayed.
D1-101995511
D1-102415701
D1-102494009
D1-102759001
D1-102896401
D1-103175201
D1-103258750
The Software hung up after eliminating track error problem when the help
video was watched. This problem is solved in 707.1.SP2; in 707.1.SP1.HF1 a
workaround is included (the video cannot be started any longer).
D1-102084601 The "z axis movement" and "filter disk check" head verification scripts could
not be started.
D1-102120223 The software hung up after switching off/on a servo on the GUI.
D1-102510901 The filter disk check for C&P20 P is done with component sensor (not with
SIPLACE Vision), hence no Vision result should be displayed.
D1-102787101 After machine start it was not possible to start production.
D1-102829301 When the station software was installed on the station computer, the
templates for the head verification report did not get installed.
D1-102868601 The setting for contamination detection of the glass plate was too sensitive.
D1-102896661 There is a function to check if there are bad tracks. If yes a window pops up
and tells about the track you should have a closer look at. If you reset the error
statistics in the GUI it had no effect on this check.
D1-102899001 Component Sensor calibration was not possible with nozzle types 4108 and
4109.
D1-103159001 The description of the Schmersal switches for input/output was not up to date.
D1-103169774 During endurance run gantry 1 always reported a wrong travel range.
D1-103205501 The LDU failed to check the planarity.