00197442-03_VD_707_1_SP2_DE_EN.pdf - 第35页

Station S oftware 70 7.1 SP2 / Ver sion Desc ription Ausgabe 11/2014 E dition 35 D1 - 104103541 In case of a yellow bo ard, the inf ormation was som etimes m issing from which machine t he error c ame. D1 -1 04132901 The…

100%1 / 92
Station Software 707.1 SP2 / Version Description Ausgabe 11/2014 Edition
34
D1-103240701 The PCB camera could not read the 2D barcode on a SIPLACE CA placement
machine.
D1-103246641 The nozzle scan was too sensitive for the nozzles 4107 and 4109.
D1-103292201 The GUI hang up when the operator clicked on a placement position of a
loaded board and the station software had to be restarted.
D1-103295401 The software hung up during the reference run of the dp axes of gantry 2.
D1-103335501 Pickup problem WPC: the fiducials were not checked correctly and the
components from the back rows were picked up with offset or even not picked
up.
D1-103358302 The position of the reject bins at location 2 could not be reached (x-axis).
D1-103375111 Although no component used the surface inspection there was an error
message that the glass plate is dirty.
D1-103511101
D1-103511141
Machine with C&P20 P placement heads got out of memory after more than
100 hours of production.
D1-103448901
D1-104132402
Head 1 and 2 could not be referenced and the machine had to be restarted.
D1-103528032 The machine had slow response when the pickup position was taught.
D1-103548201 There was a memory leak if cover foil broken was reported.
D1-103614955 Creating the bug report needed 30 minutes and the file was very big.
D1-103624481 Teaching the placement position: the false color, zoom in, zoom out, center
and 1:1 buttons were missing in 707.
D1-103627956 After having renamed the WORK directory to WORK_Original, a new directory
was created but the component counter and the working hours were 0.
D1-103679541 For all endurance runs the amount of cycles was too high. 30-50 cycles are
enough for a faster analysis..
D1-103704658 eSW: Error message 40009 - Action at nozzle changer failed, user invention
required.
D1-103749941 The software hung up and the GUI disappeared but the heads were still
working.
D1-103910801 eSW: Feeder was permanently unlocking and locking (table 1, track 60).
D1-103930301 The reject bin was not checked by the software.
D1-103970423
D1-104091489
D1-104576801
D16877-17258
D1-104555041
A small component could not be rejected automatically but even after
removing it manually the machine did not continue but was still waiting for the
component to be removed.
D1-104045501
D1-104081501
D1-104145501
D1-104256101
D1-104260409
Sporadically, the station software did not start. Sometimes it had to be
rebooted, sometimes it had to be reinstalled.
Station Software 707.1 SP2 / Version Description Ausgabe 11/2014 Edition
35
D1-104103541 In case of a yellow board, the information was sometimes missing from which
machine the error came.
D1-104132901 The WPC reported an error message when a tray with high components was
refilled.
D1-104310307 The conveyor 2 collided with the support pins. Now it can be configured that a
message window always pops up and tells the operator to remove the pins.
D1-104319313
D1-105206517
Sometimes the head stopped above the feeder pick up position.
D1-104503743 The 32608 waiting until stopped error message was displayed for
head 4 and the machine had to be restarted.
D1-104523401 During the first setup of the machine the embedded software download failed;
after reboot it was ok.
D1-104523449 The software hung up after having measured the vacuum at gantry 1.
D1-104642951 Reject rates from GUI, OIS and Explorer did not match.
D1-104893101 LED placement with placement sequence lead to a software hang-up.
D1-105195201 Machine issued the 32602 The software has stopped
unexpectedly. Shut down Windows, then restart the station
error.
D1-105647001 During production the head wanted to make a nozzle configuration check but
the head was waiting endlessly over the nozzle changer.
D1-106116303 The head stopped over the feeder table but did not do anything.
D1-106845201 eSW: There was a timeout when the "unlock all feeder" function was used.
D16840-18613 The 2x8mm x-feeder reported a foil torn error although there was none.
D16840-25113 A very high reject rate was displayed on the SIPLACE OIS GUI when boards
with ink spots were placed.
D17077-6420
D1-102963501
The C&P20 M placement heads in placement area 2 were not recognized.
D17238-1501 The software hung up when the operator scanned the component barcode
with barcode reader.
D17239-10311 The pickup point was not shown on the GUI during pickup position correction.
D17263-8714 Skipped components were not reset with the next job.
D17305-4811 A red board was displayed although no board was cancelled and the machine
produced normally.
D17305-6220 The PCB camera stopped scanning the PCB barcode.
D17383-211 There was an unhandled exception during production.
D17384-4107 The machine issued the 32602 The software has stopped
unexpectedly. Shut down Windows, then restart the station
error.
D17384-4932 The machine issued the vacuum not sufficient error.
Station Software 707.1 SP2 / Version Description Ausgabe 11/2014 Edition
36
D17486-2807
D1-103881989
The position correction did not work correctly for alternative component tracks.
D1-93860054 Events which were sent from Setup Center to Facts (foil torn) were not ok.
D1-97048506 Feeder settings upload did not work correctly.
D1-99346831
D1-98747909
D1-99789341
After every placement cycle there was a height reference run for the nozzle
2033 (the component sensor had problems to recognize the components).
D1-99367001 An undefined dp axis hardware error was displayed in the message window
during booting. However, the machine ran without any problems.
D1-99789301 The MAC Test button was available although the function could not be used.
Table 10-1: Corrected errors 707.1 SP2 station software version
10.2 707.1 SP1 Station Software
The 707.1 SP1 station software version contains all error corrections of the previous 701.xx
707.1 versions. Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-93125201 The service notification for the SX gantry was not correct.
D1-100758981 After a foil torn error the feeder LED got green although the track was locked.
D1-85092201
D1-96871701
D1-98744850
The station did not send "waiting for PCB" events and SPM and SIPLACE
Explorer just displayed "productive" status).
D1-96491101 eSW: travel range limits of the y axis were not ok; after the removal of the
prepared gantry and installation of the long buffers the newly detected travel
range was too big (> 563mm).
D17397-2558
D1-100886301
eSW: Sporadic problems with connection of feeder or LDU and FCU.
D1-96910701 eSW: after having taught the pickup position there was an unspecified
hardware error.
D1-101493102 If a head mapping in station software 706 was interrupted and continued (but
not restarted from the beginning) the machine did not work anymore after
update to station software 707.
D1-101571301 Reset all changes was set when the pickup position was taught. After that,
the original SIPLACE Pro position was displayed instead of the position
recognized by the component pocket recognition.
D1-101450551 The software displayed "No head mapping file" after mapping.
D1-103970041 Y-axis mapping could not be calibrated on an SX1/2 placement machine.
Table 10-2: Corrected errors 707.1 SP1 station software version