CP-842E-842ME Operator's Guide-Preliminary-CP842-10E.pdf - 第34页
Setting Error Processing Set the operation to be used for re-attempting part placement (referred to as recovery) after something such as a vision processing error has occurred soft return during the placement of a part. …

Preparing for Production Data Transmission
The operating status of the machine during production is saved in files referred
to as production logs. This production data is managed at the host computer.
Set the machine to the transmission mode so that the production data can be
sent to the host computer.
Procedure
1. Select [HOST] from the [Main] screen.
2. Select [ON] from the [Communication Status] section.
3. Select [Online] from the [Control Status] section.
4. Select [Remote].
5. Press [Close] to return to the [Main] screen.
Note: When the CP-842E/842ME starts up, the machine settings are as described
above. Usually it is not necessary to input these settings.
Chapter 3: Preparing for Production
Preliminary
3-3CP-842E/842ME Operator’s Guide

Setting Error Processing
Set the operation to be used for re-attempting part placement (referred to as
recovery) after something such as a vision processing error has occurred soft
return during the placement of a part. Normally this is set to auto recorvery.
<Explanation of error handling modes>
Auto Recovery: After an error has occurred, the recovery operation is
attempted up to the number of attempts specified at
[Recovery Limit]. The machine stops if the part is not
successfully placed within the specified limit. Recovery
is attempted after the machine is restarted.
Error Stop: If an error occurs the machine stops immediately
without performing recovery operation. Recovery is
attempted after the machine is restarted.
Error Pass: Recovery is not carried out even if an error occurs.
Operation is completed with the part in question left
unplaced and the panel is unloaded to the next machine
in the line. This is not used in normal production.
Procedure
1. Select [Recovery] from the [Main] screen.
2. Select the error handling mode from among the following
choices; [Auto Recovery], [Error Stop], and [Error Pass].
Note: When selecting the “Auto Recovery” mode, the “Recovery Reference”
and “Recovery Limit” settings (see below) must also be specified at that
time.
3. Press [Close] to return to the [Main] screen.
Chapter 3: Preparing for Production
Preliminary
3-4 CP-842E/842ME Operator’s Guide

Setting the “Recovery Reference” Data
A “Recovery Limit” setting must be specified when the “Auto Recovery”
mode is selected. The “Recovery Reference” setting permits the selection of
either the machine’s “Recovery Limit” setting or the Part data “Recovery
Limit” setting.
<Explanation of recovery reference data>
Machine: The recovery limit setting at the machine applies to all parts.
Part data: The recovery limit for each part is determined by the recovery
limit setting in the Part data for that part.
Note: When the [Machine] setting is selected, the recovery limit setting
described in the following section is also required.
Procedure
1. Select [Recovery] at the [Main] screen.
2. Select [Auto Recovery].
3. Select [Machine] or [Part Data] from the [Recovery Reference]
section.
4. Press [Close] to return to the [Main] screen.
Chapter 3: Preparing for Production
Preliminary
3-5CP-842E/842ME Operator’s Guide