CP-842E-842ME Operator's Guide-Preliminary-CP842-10E.pdf - 第87页

It is possible to skip specific boards from among the boards specified in the program so that no parts are placed on the specified board(s). This is referred to as the board skip function. For details on the board skip f…

100%1 / 91
This command is used to return the scheduled production quantity count to
zero.
Procedure
1.
Select [Program] from the [Changeover] section at the [Main]
screen.
2. Select [Clear Completed Panels].
3.
Select [OK] at the dialog box.
8.14 Clearing the Production Quantity
Count
Chapter 8: Production Support Functions
Preliminary
8-10 CP-842E/842ME Operator’s Guide
It is possible to skip specific boards from among the boards specified in the
program so that no parts are placed on the specified board(s). This is referred
to as the board skip function. For details on the board skip function see the
CP-842E/842ME System Reference manual.
Procedure
1. Select [Board Skip Data] from the [Mode] section at the [Main]
screen.
2. Select the number of the board that is to be skipped from the
[Board Number and Status] section.
3. If the panels for which the board skip setting applies are all the
remaining panels, select [Remaining Panels] from the [Target
Panel] section. If the board skip setting is to be applied to only
the panel currently being produced then select [Current Panels].
4. Press [Close].
5. Initiate production by entering [Production] from the [Main]
screen and production will be carried out without placing parts
on the specified board(s).
8.15 Skipping Boards
Chapter 8: Production Support Functions
Preliminary
8-11CP-842E/842ME Operator’s Guide
This operation mode allows panels to pass through the machine from the pre-
vious machine station to the next machine when there are no parts in the rele-
vant program that are specified to be placed using the machine. This opera-
tion is referred to as the "Pass Mode Operation".
Procedure
1. Select [Operation] from the [Mode] section at the [Main] screen.
2. Select [Pass] in the [Operation Mode] section.
3. Press [Close].
4. Enter [Production] and production will commence using pass
mode operation.
8.16 Pass Mode Operation
Chapter 8: Production Support Functions
Preliminary
8-12 CP-842E/842ME Operator’s Guide