Frequency Every 8 hours Procedure W ARNING Be sure to turn the 200V power off before performing this procedure. Pull the lever forward then slide the reject parts box sideways and pull it out as shown below . 7.3 Emptyin…

100%1 / 91
Frequency
Every 8 hours
Procedure
WARNING
Be sure to turn the 200V power off before performing this
procedure.
Use a vacuum cleaner to suck up any waste tape scattered around the waste
tape suction path.
7.2 Cleaning the Waste Tape Suction Path
Chapter 7: Maintenance
Preliminary
7-3CP-842E/842ME Operator’s Guide
Frequency
Every 8 hours
Procedure
WARNING
Be sure to turn the 200V power off before performing this
procedure.
Pull the lever forward then slide the reject parts box sideways and pull it out
as shown below.
7.3
Emptying the Reject Parts Box
Chapter 7: Maintenance
Preliminary
7-4 CP-842E/842ME Operator’s Guide
Frequency
Once a week
Procedure
Use an appropriately sized drill bit to remove foreign matter from inside the
nozzle tube. When cleaning is complete, check the nozzle tip to ensure that
dirt from the nozzle has not adhered to the tip.
Notes:
1. Take care to avoiding bending the nozzle.
2. Take care to avoiding dirtying the surface of the florescent seal.
7.4 Cleaning Nozzles
Chapter 7: Maintenance
Preliminary
7-5CP-842E/842ME Operator’s Guide