Frequency Once a week Procedure Use an appropriately sized drill bit to remove foreign matter from inside the nozzle tube. When cleaning is complete, check the nozzle tip to ensure that dirt from the nozzle has not adher…

100%1 / 91
Frequency
Every 8 hours
Procedure
WARNING
Be sure to turn the 200V power off before performing this
procedure.
Pull the lever forward then slide the reject parts box sideways and pull it out
as shown below.
7.3
Emptying the Reject Parts Box
Chapter 7: Maintenance
Preliminary
7-4 CP-842E/842ME Operator’s Guide
Frequency
Once a week
Procedure
Use an appropriately sized drill bit to remove foreign matter from inside the
nozzle tube. When cleaning is complete, check the nozzle tip to ensure that
dirt from the nozzle has not adhered to the tip.
Notes:
1. Take care to avoiding bending the nozzle.
2. Take care to avoiding dirtying the surface of the florescent seal.
7.4 Cleaning Nozzles
Chapter 7: Maintenance
Preliminary
7-5CP-842E/842ME Operator’s Guide
Frequency
Once a week
Procedure
WARNING
Be sure to turn the 200V power off before performing this
procedure.
Use a soft brush (such as those used to clean camera lenses) to clean the cam-
era glass. If the glass is badly soiled, use a commercially available glass clean-
er.
CAUTION
Take care not to bend the nozzle by touching it at the
tip.
• Because the camera glass is thin and easy to break, do
not push hard when wiping it clean.
7.5 Cleaning the Camera Glass
Chapter 7: Maintenance
Preliminary
7-6 CP-842E/842ME Operator’s Guide