IFS - NX P rodu ct S pecificat ions 41 9-2-1 Intelli t rolley (RFID) This is a feeder exchan ge trolley correspo nding to an RFID. The infor m ation on an RFID that has been rec ognize d auto m atica ll y is trans mitted…

IFS-NX Product Specifications
40
Unit
The
number
of slots
RFID
CAN
*5
Remarks
Factory-
installed
Retrofit
Factory-
installed
Retrofit
Mechanical feeder bank (Feeder exchange trolley method)
FX-1R/2
40
○
*2
×
*4
× ×
FX-3/3R/3RA
60
○
*2
○
*3
× ×
KE-2050/60
80 ○
*2
×
*4
× ×
KE-2050R/55R/60R
KE-1070/80
KE-2070/80/80R
KE-3020/20R
80
○
*2
○ × ×
KE-3010/3020V/20VR
80 ○
*2
○ × ×
KE-3010A/3020VA/20VRA
JM-20
80
○
*2
○ × ×
JM
-100
28
× × × ×
42
× × × ×
Feeder calibration jig with a monitor
(JM01)
○ ×
*4
- -
Mechanical feeder stocker
80
○ ×
*4
× ×
(○: option △:Customization ×: No correspondence. -: Correspondence plan).
*1 The number of an electric feeder slot is equivalent to two slots of a mechanical feeder.
*2 Only a feeder exchange trolley with a connector bracket (an option) can be used.
*3 Mounting the antenna array to read RFID is a factory-set option.
*4 Return the bank to us to additionally process it to attach an antenna array for reading an RFID on the device.
*5 When the system is used in CAN, you have to add a feeder bank ID board to an electric feeder bank (EF). Since a
feeder bank ID board is mounted on an electric feeder bank (RF) as a standard device, you do not have to add any
board to the electric feeder bank (RF).
*6 Since any feeder cannot be mounted at an even-numbered slot of an electric feeder bank (EF) when you use an
RX-7/7R, up to 19 feeders can be used with the RX-7/7R.
*7 RX-7 doesn’t have a fixed bank specification.

IFS-NX Product Specifications
41
9-2-1 Intelli trolley (RFID)
This is a feeder exchange trolley corresponding to an RFID.
The information on an RFID that has been recognized automatically is transmitted to an IFS server via
an Intelli trolley pool.
9-2-2 Intelli trolley (CAN)
This is a feeder exchange trolley corresponding to CAN.
When the system is used in CAN, you have to add a feeder bank ID board to an electric feederbank
(EF). Since a feeder bank ID board is mounted on an electric feeder bank (RF) as astandard device,
you do not have to add any board to the electric feeder bank (RF).
The information on the feeder and feeder bank that has been recognized through the CAN is
transmitted to an IFS server through a PW02.
9-2-3 Intelli trolley pool (RFID)
This Intelli trolley pool for the RFID is composed of an MPU for the RFID and cables.
Up to four sets of Intelli trolleys (RFIDs) can be connected to the system by using one Intelli trolley pool.
Model
MPC+
MPC-4C
Power supply
*1
Voltage
Single-phase 100 to 240 V
AC
±
10%
Single-phase 100 to 240 V
AC
±
10%
Frequency
50/60 Hz
50/60 Hz
Apparent power
45 VA
45 VA
Dimension
Width (W)
106 mm
106 mm
Length (L)
126 mm
126 mm
Height (H)
33.6 mm
56 mm
Mass
Approx. 310g
310 g
RFID
characteristics
Operating
frequency
125 KHz 125 kHz
Safety specification
European Low Voltage
Directive 2006/95/EC
EMC Directive 2004/108/EC
R&TTE Directive 1999/5/EC
CE marking applied
*1 A power cable of the Japanese specification is supplied with the Intelli trolley
pool. (The power cable of the overseas specification needs to be arranged at the
site.)
9-2-4 PW02
This PW02 is composed of an MPC-CAN, power supply unit, and cables.
The MPC-CAN is built into the PW02.
Up to two sets of Intelli trolleys (CANs) can be connected to the system by using one PW02.
One PW02 allows up to two Intelli trolleys (CAN) and up to two Intelli trolleys (RFID) to be connected to
the system.
Power supply *1
Voltage
Single-phase 100 to 240 V AC
±
10%
Frequency
50/60 Hz
Apparent power
600 VA
Dimension
Width (W)
290 mm
Length (L)
300 mm
Height (H)
530 mm
Mass
Approx. 15 kg
RFID characteristics
Operating frequency
125 kHz
Safety specification
CE marking applied
*1 For details about power cable and PW02, see the Instruction Manual for PW02.

IFS-NX Product Specifications
42
9-2-5 Intelli stocker
(1) For a mechanical tape feeder
This is a storage stand to store a feeder equipped with the reading function of an RFID and can
be moved with casters. (An Intelli stocker can be attached (or stored) on a feeder that does not
support any RFID.)
120 units can be stored at 8-mm feeder conversion. (Three-floor type, but it is used as a
two-floor type when a large-size feeder is installed.)
Power
supply *1
Voltage
Single-phase 100 to 240 V AC
±
10%
Frequency
50/60 Hz
Apparent power
45 VA
Dimension
Width (W)
850 mm or less *2
Length (L)
1,500 mm or less *3
Height (H)
1,350 mm or less *4
Mass
94 kg
Safety specification
CE marking applied
*1 A power cable of the Japanese specification is supplied with the Intelli trolley pool. (The
power cable of the overseas specification needs to be arranged at the site.)
*2 A size of a carrying handle is not included.
*3 A convex shape part of a reel retainer section is included.
*4 This indicates the height of the level area of a mechanical tape feeder main unit.
(2) For an electric tape feeder
This is a storage stand to store a feeder for an electric bank equipped with the reading function
of an RFID and can be moved with casters.
80 feeders (converted in terms of 8-mm feeders) can be stored.
Power
supply *1
Voltage
Single-phase 100 to 240V AC
±
10%
Frequency
50/60 Hz
Apparent power
45 VA
Dimension
Width (W)
950 mm or less *2
Length (L)
1,500 mm or less *3
Height (H)
1,200 mm or less *4
Mass
80 kg
Safety specification
CE marking applied
*1 A power cable of the Japanese specification is supplied with the Intelli trolley pool. (The
power cable of the overseas specification needs to be arranged at the site.)
*2 A size of a carrying handle is included. The full width of only a main unit is 830 mm.
*3 A convex shape part of a reel retainer section is included.
*4 It shall indicate the height of the topside of the fall-prevention-type horizontally-sliding
section level area of the feeder.
9-2-6 Intelli feeder calibration jig with a monitor
It is a feeder calibration jig with a monitor that supports an RFID.
Recognition of a feeder ID and record of an inspection day are performed automatically, and working
efficiency improves.