IFS-NX_SPE_EN.pdf - 第50页

IFS - NX P rodu ct S pecificat ions 46 10 -4-3 PWB Barcode [C onveyor exte nsion barco de reader method ] 10 -4-3-1 Usable Bar code Types The usab l e barc odes are provided in the fol l owing t hree types of formats . B…

100%1 / 54
IFS-NX Product Specifications
45
PWB code
10-4-1 Common subject matter
10-4-1-1 Usable characters
The characters that can be used as a PWB code are half-size alphanumeric characters, and up to 250
characters can be used.
(* However, the number of characters varies depending on the code type.)
10-4-1-2 Notes when a code is pasted on a PWB
When you paste a code on a PWB, be careful of the following items.
- The whole code is attached on the PWB.
- The code covers neither the placed component nor a mark.
- The code is not overlapped with the clamp area of a PWB (See the following figure).
- For a barcode, pay attention to the pasting angle.
Since other specifications comply with the specification of a camera for reading codes, see each
section described below.
10-4-2 Applicable Machine Types
Reading system/PWB
code
Barcode reader
for conveyor
extension
OCC
Multi code
reader
Bottom view
multi code
reader
Applicable machine types
Barcode
2D code
Multi code
Multi code
KE-1070/1080
KE-2050/2060
KE-2050R/2055R/2060R
KE-2070/2070C/2080/2080R
KE-3020/3020R
KE-3010/3020V/3020VR
KE-3010A/3020VA/20VRA
FX-1R
FX-2
FX-3/3R/3RA
JM-20
JM-100
RX-6/6B/6R
RX-7/7R
RS-1/1R
3 mm
3 mm
Clamp area
IFS-NX Product Specifications
46
10-4-3 PWB Barcode [Conveyor extension barcode reader method]
10-4-3-1 Usable Barcode Types
The usable barcodes are provided in the following three types of formats.
Barcode formats: CODE39, CODE128, and NW-7 (Check digit: None)
(Note) When a check digit exists, it is regarded as part of data.
Data expressed by a barcode is as follows. A start character and a stop character are not included, and
up to 32 characters can be used. The types of usable character on each barcode are as follows.
Item
Type of usable character
Type
CODE39
0 to 9, A to Z, -, ., space, $, /, +, %
43
CODE128
All of ASCII characters (a number, a capital/small
character, a symbol, a control character)
However, the following characters cannot be used:
"<" , ">", """, "'", and "&."
128
NW-7
0 to 9, - , $, /, ., +, :
(a to d are start/stop characters)
16
10-4-3-2 Readable barcode size
The following sizes can be read according to the PWB transport direction (width and length).
Transport direction: Width
T
ransport direction: Length
(N
ote) The length of a barcode includes a quiet zone.
A quiet zone indicates margins on either side of a barcode symbol, and requires the space
that is wider than 10 times the narrow bars on the right and left sides.
PWB transport direction
PWB transport direction
Max. 70 mm
Min.
3 mm
PWB
(Note)
The length of a barcode
includes a quiet zone.
(Note)
The length of a barcode
includes a quiet zone.
Max. 74 mm
Min. 7 mm
PWB
IFS-NX Product Specifications
47
10-4-3-3 Attachment angle to a PWB
The barcode is attached on a PWB as follows:
Attachment angle
An attachment angle is either parallel to a PWB (0 degrees or 180 degrees) or perpendicular to a
PWB (90 degrees or 270 degrees) as follows:
Parallel (0 degrees)
Parallel (180 degrees)
Perpendicular (90 degrees)
Perpendicular (270 degrees)
10-4-3-4 Others
Reading bar width: 0.15 mm to 1.00mm
PCS (Print Contrast Signal): 0.6 (Reflectance of white: 75% or more)
(Reflectance of space) (Reflectance of a bar)
PCS=―――――――――――――――――――――
(Reflectance of space)
10-4-4 PWB 2D code [OCC method]
(1) Readable marks
The specification of the marks that can be read as a PWB 2D barcode is as follows:
No.
Item
Remarks
1
Usable code
QR code (Version 1 to Version 7)
MicroQR code (Version M1 to M4)
DataMatrix (ECC50, 80, 100, 140, 200)
9 x 9 to 48 x 48
8 x 18 to 16 x 48
Version 1=21 x 21
Version 7=45 x 45
2
Cell size
0.065 mm (5 pixels) to 0.5 mm
3
Usable character
Alphanumeric character (Chinese character
and binary character cannot be used.)
4
Maximum number
of characters *1
250 characters
5
Code size
RX-6 series
RS-1 series
9.5 mm or less
Quiet zone is
included.
RX-7/7R
8.0 mm or less
JM-100
6.3 mm or less
Other than the above.
5.5 mm or less
*1 This is the number of digits of a serial number of a PWB that can be processed with the
IFS-NX.
The 2D codes in which a cell has been painted out completely and also those in which a black
cell has been drawn with dots can be recognized as shown in the following left figure. In this
case, the diameter of a dot should be the same as the cell size.
(2) Read-in method
The OCC is moved to the position of the code that offsets a PWB mark after a PWB is fixed to a
center buffer and shoots a picture of it.
The coordinates at which a mark is detected are saved with a KE-2050/ 2060/ 205R/ 2055R/
2060R series mounter as the values unique to the mounter (that is, stored in the Machine Setup