KY Config_Manual_ENG_Final.pdf - 第33页
- Use Auto Pause - Use IT AC - Mando -Hella - Huf Me xico Use Printer C losed Loop Feedback (Console T ype) Select this item for using Closed Loop with S peedline MPM Printer . • Use Barcode Option: Select for using barc…

5.3. 3D View Ground Limit
This section describes 3D View Ground Limit in the pop-up window displayed by clicking ETC Setup button on the main screen.
Field Name
Field Description
3D View Ground Limit
Set this item to display 3D view from the setting Ground location.(default unit: um)
5.4. DVQueue Delete Option
This section describes DVQueue Delete option in the pop-up window displayed by clicking ETC Setup button on the main screen.
Field Name
Field Description
DVQueue Delete with
GUI Start
This item is selected to delete DVQueue folder when 3D Inspection System is started.
5.5. Check DVQueue Folder Count
This section describes Check DVQueue Folder Count item in the pop-up window displayed by clicking ETC Setup button on the main screen.
Field Name
Field Description
Check DVQueue
Folder Count
This item is selected for sending out PCB after checking Folder Count on DVQueue. (When there is only one
PCB left on searched Folder, the PCB is sent out.)
• With Message: This item is selected for displaying Message when DVQueue Folder is searched during sending
out.
• Msg Timer: This option is selected to set Timer when “Check DVQueue Folder Count” is used. If the PCB is not
sent out after checking Folder Count during set time, the Error Message pop-up.
5.6. Use MES System
This section describes Use MES System item in the pop-up window displayed by clicking ETC Setup button on the main screen.
Field Name
Field Description
Use MES System
Select this item for using MES.
• Select SITE: Select the customer site. Each function activates based on each customer. (This is customer
optimization option.)
- MES Job Link Option
- Use Auto Run

- Use Auto Pause
- Use ITAC
- Mando-Hella
- Huf Mexico
Use Printer Closed
Loop Feedback
(Console Type)
Select this item for using Closed Loop with Speedline MPM Printer.
• Use Barcode Option: Select for using barcode option.
• Use Dual Lane: Select for using Dual Lane.
• Use Disconnect Mode: This option is selected for processing PCB, which user manually put on the system, not
transferred from Printer on Closed Loop mode. On Use Disconnect Mode, corresponding data will not transfer to
Printer.
• COMPUTER NAME: Sets computer name of Printer.
• SERVER PORT: Sets server port.
• CLIENT PORT: Sets Client port.
Continental Icheon
This item is selected for linking with MES at Continental Icheon.
Closed Loop (XML
Type)
This option is the most generally utilized Closed Loop.
• Use Barcode: Select this item for using barcode.
• Use Export Array Type: Select this item for exporting files as one array for one PCB.
• Select Vendor: This item is selected for setting Printer vendor place advance to SPI inspection system.
• Lane 1 SPI Export Folder: Sets Export folder on Closed Loop Single Lane SPI inspection System.
• Lane 1 Printer Export Folder: Sets Export folder on Closed Loop Printer place advance to Single Lane SPI
inspection System.
• Lane 2 SPI Export Folder: Sets Export folder on Closed Loop Dual Lane SPI inspection System.
• Lane 2 Printer Export Folder: Sets Export folder on Closed Loop Printer place advance to Dual Lane SPI
inspection System.

5.7. Control
This section describes Control item in the pop-up window displayed by clicking ETC Setup button on the main screen.
Field Name
Field Description
Pad Verification
Button Control
• Default
- This item is selected to pass to following Defect Pad by clicking Next button after selecting GOOD/BAD of
Defect Pad on Defect View, Defect Review, Easy Use.
• View Next Defect Automatically On Click
- This item is selected to pass automatically to following Defect Pad once clicking GOOD/BAD on Defect
View, Defect Review, Easy Use.
PASS / NG Button
Control
• Default
- This item is selected to activate NG / PASS button from the beginning of Defect PCB on Defect View, Defect
Review, Easy Use.
• Activate PASS button after Reviewing all defects
- This item is selected to activate PASS button after reviewing all Defect Pad on Defect View, Defect Review,
Easy Use.
• Activate PASS button after Reviewing [] defects
- This item is selected to activate PASS button after reviewing the setting Defect Pad on Defect View.
• Activate PASS button after Verifying all defects
- This item is selected to activate PASS button after verifying all defects as GOOD /BAD on Defect View,
Defect Review, Easy Use.
• Activate PASS / NG button after Reviewing all defects
- This item is selected to activate NG / PASS button after reviewing all defects on Defect View, Defect
Review, Easy Use
• Activate PASS / NG button after Verifying all defects
- This item is selected to activate NG / PASS button after verifying all defects as GOOD /BAD on Defect View,
Defect Review, Easy Use.
• Disable PASS if defects are more than []
- This item is selected to disable PASS button on Defect View when number of Defect Pad is more than set
value.
- With Message: When PASS button is disabled, the message box will be popped-up.
- Defect Limit Type: This item is selected to set PASS Limit type for all PCB or Panel.
• Automatic selection after reviewing all defects
- Select this item for automatically selecting NG / PASS button of Defect PCB after reviewing all defects when
clicking Next button on Defect Pad on Defect View, Defect Review, Easy Use.