User Manual SIPLACE S-25 HM 3 What to do when ...
Software Version SR.503.xx 04/2002 US Edition 3.1 Switching on the SIPLACE line
105
NOTE
The current state of the station is displayed in the status field in the "State" line, and the action you
are to execute is displayed in the "Action:" line (see Fig. 3.1 - 2). 3
Æ Press one of the start keys (white) when prompted with "Press start key".
(The start keys are located on the input side and output side of the placement system.)
A reference sequence is executed on all axes. The station is ready for operation after the ref-
erence sequence has completed.
The symbol is displayed in the work area of the user interface.
3.1.5 "Switching on the SIPLACE line" flow chart
The following flow chart shows the actions executed be the line computer, station and operator while
the SIPLACE line is being switched on and started up.

3 What to do when ... User Manual SIPLACE S-25 HM
3.1 Switching on the SIPLACE line Software Version SR.503.xx 04/2002 US Edition
106
Fig. 3.1 - 3 "Switching on the SIPLACE line“ flow chart
Test set-up
Reset tracks
No
Line computer tasks
Load cluster data
Fiducials
OK?
Make settings on the machine
Set-up generator appears
Check the set-up
(insert feeder modules)
Switch on
Nozzle check
Change nozzle
configuration, if necessary
Wait for PCB
Introduce PCB
Track
errors
Yes
Abort
placement
Yes
PCB onto output conveyor
No
Station computer
Bold:
Italic:
To be carried out
by the operator
Carried out or
signaled by the
station
Confirm the
set-up generator

User Manual SIPLACE S-25 HM 3 What to do when ...
Software Version SR.503.xx 04/2002 US Edition 3.2 Switching off the SIPLACE line
107
3.2 Switching off the SIPLACE line
ATTENTION
Before you switch off the line, ALWAYS make sure that:
– All placement operations on the stations are completed.
– The Z-axis of all placement heads are in the top end position.
– None of the placement heads still contain components.
– All gantries have moved into the standby position.
– The station computers have been properly shut down.
3.2.1 Switching off the line computer (UNIX)
CAUTION
NEVER just switch off the line computer on the power switch (of the UPS).
ALWAYS shut down the operating system of the line computer with "Shutdown". Otherwise you
will almost certainly lose a lot of data and may need to reinstall the line computer software.
Æ Position the mouse at the right or lower edge of the screen.
The cursor will change into a cross.
Æ Press and hold down the left mouse button. The main menu appears.
Æ Move the mouse cursor onto the ’Shutdown’ menu item and then release the mouse button.
The following dialog box appears on screen:
Æ Click on yes. The dialog box closes and the operating system shuts down. This operation takes
around 1 minute. The following then appears:
Æ Switch off the UPS.
really shutdown?
yes no
** Safe to Power Off **
-or-
** Press Any Key to Reboot **