00193463-01.pdf - 第142页

4 Component handling User Manual SIPLACE S-25 HM 4.3 Setting up the f eeders Software Version SR.503.xx 04/2002 US Edition 142 4 Fig. 4.3 - 1 Inserting 30 or 4 5 mm wide feeders on the component table (1) Feeder , 3 0 mm…

100%1 / 226
User Manual SIPLACE S-25 HM 4 Component handling
Software Version SR.503.xx 04/2002 US Edition 4.3 Setting up the feeders
141
4.3 Setting up the feeders
4.3.1 Preparing the component table and feeder for set-up
Æ Select the setting range for the feeder to be used
(see Vibrator configuration).
Æ Move the placement head to the waiting position and press the emergency stop button.
Æ Open the protective covers.
Æ Clean the contact surface for the feeders and the contact surface for the feeders on the com-
ponent table.
Æ Place the feeder on the previously selected track on the component table (see Vibrator config-
uration).
4.3.2 Insert the feeder
Æ Insert the feeder so that the back of the feeder is held by the centering ball and the front is fixed
in place by the corresponding centering pin on the component table. Make sure that the feeder
is placed on the component table in the correct position for its width.
Æ Check that the feeder is firmly seated on the component table.
Æ Connect the feeder plug to the socket beneath the location.
PLEASE NOTE 4
When you connect the feeder, make sure that you use the right socket for the location since
the feeder receives the control pulse via this socket. The feeder may not work correctly if it is
not connected to the right socket. 4
Æ Close the protective covers and switch the control on again.
Æ Carry out a refill check if necessary.
Æ Continue placement.
4 Component handling User Manual SIPLACE S-25 HM
4.3 Setting up the feeders Software Version SR.503.xx 04/2002 US Edition
142
4
Fig. 4.3 - 1 Inserting 30 or 45 mm wide feeders on the component table
(1) Feeder, 30 mm wide
(2) Feeder, 45 mm wide
(3) Feeder, 30 mm wide
(4) Centering ball
(5) Component table
User Manual SIPLACE S-25 HM 4 Component handling
Software Version SR.503.xx 04/2002 US Edition 4.4 Tape container
143
4.4 Tape container
4.4.1 Overview
Reels up to 15" in diameter may be used, although for 15" reels you should use spindles as well.
Insert the spindles into the partitions as shown in Fig. 4.4 - 1. 4
PLEASE NOTE 4
We recommend that you use spindles if the tape reel diameter exceeds 5". This will ensure that
the feeders operate reliably. 4
Fig. 4.4 - 1 Component table and tape container
(1) Component changeover table
(2) Spindle
(3) Waste tape container
(4) Partition
(5) Tape container