User Manual SIPLAC E S-25 HM 5 Station extensions Software Version SR.503.xx 04/2002 US Edition 5.9 Nozzle changer for the 6-segment Collect&Place head 197 5.9.4 Notes on operation Æ Y ou can fi ll the nozzle magazin…

5 Station extensions User Manual SIPLACE S-25 HM
5.9 Nozzle changer for the 6-segment Collect&Place head Software Version SR.503.xx 04/2002 US Edition
196
Fig. 5.9 - 2 Magazine and nozzle garages
(1) Positioning fiducial
(2) Locking plate
(3) 9xx or 8xx nozzle garage
(4) Hole for the parallel pin for centering the magazines
(5) Hole for the parallel pin of the slide mechanism
(6) Slot for the parallel pin for centering the magazines

User Manual SIPLACE S-25 HM 5 Station extensions
Software Version SR.503.xx 04/2002 US Edition 5.9 Nozzle changer for the 6-segment Collect&Place head
197
5.9.4 Notes on operation
Æ You can fill the nozzle magazine with different types of nozzles from the same family, e.g. fill
no. 8 magazines with nozzle types 821, 822, 823, etc., and no. 9 magazines with nozzle types
911, 914, etc.
PLEASE NOTE 5
Fill the magazines off the machine and always replace complete magazines. 5
Æ Open the locking plate and place the nozzles in the nozzle garages.
Æ Close the locking plate so that the nozzles cannot drop out of the magazines.
CAUTION 5
Before you fill magazine, make sure that all the nozzles on the Collect&Place head have
been returned to their magazines. 5
Æ See the UNIX line computer operating instructions for programming the nozzle changers on
the line computer.
PLEASE NOTE 5
Æ Do not allow components to drop onto the magazines. If they do, they could jam the locking
plate.
Æ Do not allow components to drop onto free feeder locations because they will stick to the mag-
netic bar. Production may have to be interrupted if the feeders are not placed on the compo-
nent table correctly. You should therefore regularly clean the magazines and free locations.

5 Station extensions User Manual SIPLACE S-25 HM
5.9 Nozzle changer for the 6-segment Collect&Place head Software Version SR.503.xx 04/2002 US Edition
198
5.9.5 Emptying the reject bin
The capacity of the reject bin is approx. 50 nozzles of the 9xx nozzle type or approx. 5 nozzles of
the 8xx nozzle type. The reject bin must be regularly emptied in order to prevent faults during the
placement sequence. 5
Fig. 5.9 - 3 Emptying the reject bin
(1) Remove the reject bin
5
Æ Pull the reject bin out of its retainer in the direction indicated by the arrow, and lift the bin out
of its holder.
Æ To return the reject bin, push it back into the retainer.