00193463-01.pdf - 第204页

5 Station extensions User Manual SIPLACE S-25 H M 5.11 DCA v ision module on th e 12-segment C ollect&Place head S oftware Vers ion SR.503.xx 04/2002 US E dition 204 5.1 1.3 T e chnical dat a – DCA vision module 5 Fi…

100%1 / 226
User Manual SIPLACE S-25 HM 5 Station extensions
Software Version SR.503.xx 04/2002 US Edition 5.11 DCA vision module on the 12-segment Collect&Place head
203
5.11.1 Description of the 12-segment Collect&Place head with
DCA vision module
With the DCA vision module, the 12-segment Collect&Place head is able to optically center and
place components of the order of magnitude of 0.6mm x 0.3mm to 13mm x 13mm. The DCA
package optimizes the speed and accuracy when placing high-speed flip chips and bare die
components.
5.11.2 Technical data for the 12-segment Collect&Place head with
DCA vision module
Component range 0201 to 13 mm x 13 mm
Component specification
Max. height
Min. lead pitch
Min. bump pitch
Min. ball/bump diameter
Min. dimensions
Max. dimensions
Max. weight
6 mm
0.4 mm
0.2 mm
0.11 mm
0.6 mm x 0.3 mm
13 mm x 13 mm
2 g
Travel of the Z axis Max. 16 mm
Programmable placement force 2.4 to 5.0 N
Nozzle types 9xx
Max. placement rate 12,500 components/hour
Angular accuracy ± 0.7° / 4
σ
Placement accuracy of the DCA vision
module
± 90 µm / 4
σ
5 Station extensions User Manual SIPLACE S-25 HM
5.11 DCA vision module on the 12-segment Collect&Place head Software Version SR.503.xx 04/2002 US Edition
204
5.11.3 Technical data – DCA vision module
5
Fig. 5.11 - 2 Component vision module (DCA camera)
5
5
5
Component dimensions 0.6 mm x 0.3 mm to 13 mm x 13 mm
Component range 0201 up to 13 mm x 13 mm, flip-chip, bare die
Min. lead pitch 0.4 mm
Minimum bump pitch 0.2 mm
Min. ball/bump diameter 0.11 mm
Field of view 15.7 mm x 15.7 mm
Illumination method Front lighting (4 levels programmable as required)
User Manual SIPLACE S-25 HM 5 Station extensions
Software Version SR.503.xx 04/2002 US Edition 5.12 DCA vision module on the 6-segment Collect&Place head
205
5.12 DCA vision module on the 6-segment
Collect&Place head
5
Fig. 5.12 - 1 DCA vision module on the 6-segment Collect&Place head
5
(1) DCA vision module
(2) 6-segment Collect&Place head