JO-072-006_w.pdf - 第111页
4-25 AKBEG-ID (2) Raise the suppressor and perform the measurement as shown below . Measurement with GT -08080 (Exa mple) Push down the feeder with your hand. Fig. D30 (3) See the gures below for the spots to be measure…

4-24
AKBEG-ID
3. Measurement of Pickup Position Height
3.1 Required Measuring Apparatuses
•
Block Gauge 104.00 mm
Ref.:
Several block gauges can be piled up to be 10
4
.00 mm.
•
Pry-Type Dial Gauge 0.01 mm
•
Stand (used for the pry-type dial gauge)
•
Surface Plate Size: 300 mm × 300 mm or more
3.2 Measuring Method
Perform the measurement on the surface plate.
Procedure
(1) Adjust the pointer of the pry-type dial gauge to "0" (zero), using the
block gauge (104.00).
Block Gauge
104.0 mm
Adjust the pointer
to "0" (zero).
Pry-Type Dial Gauge
Measurement on the surface plate
Fig. D29
CAUTION
Carefully handle the dial gauge because the tip of
the probe is very sharp. Your hand will get injured if
the tip is inserted.
0508-001
3. Measurement of Pickup Position Height

4-25
AKBEG-ID
(2) Raise the suppressor and perform the measurement as shown below.
Measurement with GT-08080 (Example)
Push down the feeder
with your hand.
Fig. D30
(3) See the gures below for the spots to be measured.
•
Measuring Position for G*-0808*
Measuring Position on
Lane #2 Side
Measuring Position on
Lane #1 Side
Fig. D31
•
G*-12160 or more
Measure the area beside
the fiducial mark.
Magnified View
Fig. D32
0508-001
3.2 Measuring Method

4-26
AKBEG-ID
(4) Check the reading of the pry-type dial gauge.
Example 1:
When the dial gauge reads "-0.02 mm" as shown below, it
is required to enter the of
fset value "20".
Fig. D33
Example 2:
When the dial gauge reads "+0.03 mm" as shown bellow,
it is required to enter the of
fset value "-30".
Fig. D34
0508-001
3.2 Measuring Method