4-6 AKBEG-ID 2. Feeder Measurement Notice No f eeder measu rement can b e per formed unles s the regis trati on (ji g origin adjustment) of the master position is completed. Procedure (1) When you press the [Setting] but…

100%1 / 137
4-5
AKBEG-ID
(6) Press the [Return] button in the "Master Setting" window.
(7) The following message appears in the "Initial Master Setting" win-
dow, indicating that the registration of the master position is com-
pleted.
Detach the pickup position master from the jig.
Fig. D7
CAUTION
Be sure to slowly lift the pickup position master to
detach from the jig. Otherwise, the pickup position
master will come off abruptly and collide with the
camera used to capture an image of the pickup
position. The camera may be damaged.
0508-001
1. Registration of Master Position (Jig Origin Adjustment)
4-6
AKBEG-ID
2. Feeder Measurement
Notice
No feeder measurement can be performed unless the registration (jig
origin adjustment) of the master position is completed.
Procedure
(1) When you press the [Setting] button in the "Initial Master Setting"
window, the "Type Setting #1" window opens.
Fig. D8 "Type Setting #1" Window
Reference
Refer to "4. "Type Setting" Window" in "Section 3" for details.
(2) Press the [Setting] button in the "Type Setting #1" window. The "Type
Listup" window opens.
0508-001
2. Feeder Measurement
4-7
AKBEG-ID
(3) Select the No. of the type name to be measured and press the [Type
Change] button to change the program.
To measure both lane origin and X/Y offsets for "GT-08080", select "GT-08080-
8x2_ORG/XY".
Reference
(a) See the next page for program types (defaults).
(b) Refer to "3. "Type Listup" Window" in "Section 3" for the "Type Listup"
window.
Fig. D9
0508-001
2. Feeder Measurement