2-10 AKBEG-ID 1.3.1 Replacement of Battery in Micrometer (1) Put a coin, etc., in the groove of the battery lid and turn it in the A-marked direction (counterclockwise) in the gure below until the lid comes off. (2) T a…

100%1 / 137
2-9
AKBEG-ID
1.3 Attachment of Micrometer
CAUTION
•
Do not give a strong shock to the micrometer
by hitting against human body or an object.
Otherwise, the micrometer may be damaged,
resulting in inaccurate adjustment of the
component pickup position.
•
T
ighten the setscrew until the micrometer can be
moved smoothly.
Excessive tightening may damage the
micrometer.
Attachment of Micrometer Connection of Micrometer Cable
Fig. B13 Attachment of Micrometer
Procedure
(1) Attach the micrometer to the measuring jig.
(2) Secure the micrometer with the setscrew.
(3) Connect the cable to the micrometer.
(4) Hold the end of the cable with your ngers and tighten the screw so that
no clearance can be left between the cable and the micrometer.
After the attachment is completed, check how the micrometer works.
1.3 Attachment of Micrometer
0809-002
2-10
AKBEG-ID
1.3.1 Replacement of Battery in Micrometer
(1) Put a coin, etc., in the groove of the battery lid and turn it in the
A-marked direction (counterclockwise) in the gure below until the lid
comes off.
(2) Take out the old battery.
(3) Put a new battery and set the lid. After that, turn the lid in the B-marked
direction (clockwise) to secure.
Notice
(a) When the battery is reset, the reference position is cleared.
(b) SR44 (Silver Oxide Button Cell Battery) must be used.
(c) When an error display appears or an error message such as "No
Counting" is issued, remove the battery once and set it back in place.
AA
B
B
Battery Lid
Fig. B14 Back Side of Micrometer
Procedure
1.3 Attachment of Micrometer
0809-002
2-11
AKBEG-ID
2. How to start and end the system
2.1 Starting the Program
(1) Set the power switch of the electrical box to "ON" and start the personal
computer. The program starts up automatically and the "Initial Master
Setting" window opens.
The displayed name of the feeder adjusting jig is different from the actual one.
Fig. B15 "Initial Master Setting" Window
2. How to start and end the system
Procedure
0809-001