2-9 AKBEG-ID 1.3 Attachment of Micrometer C A U T I O N • Do not give a strong shock to the micrometer by hitting against human body or an object. Otherwise, the micrometer may be damaged, resulting in inaccurate adjust…

100%1 / 137
2-8
AKBEG-ID
1.2.1 Schematic Cable Distribution
LIGHT
CN12 CN21
CN11
OUT
12
DC 9V
34
X21
X12
X11
LIGHT
LIGHT
MUX10F
2Y
MUX10F
1X
PC
CAMERA
CAMERA
X23
X22
X22
MONITOR
X13
From 100-240V
Keyboard
Mouse
Personal
Computer
Adjusting Jig
Electrical Box
Micrometer Unit
(Measured Data
Transfer Unit)
Liquid Crystal Display
Power Supply: 100 or 200 V AC
(Note)
Camera Control Unit
(Power Supply for
LED Illumination)
Fig. B12
CAUTION
Check the power source for correct connection with
the specied voltage.
Notice
Cable "X23" must be connected only to the specied port of the
personal computer.
It must be connected to the above-indicated port.
An IEC60320 (old IEC320) type power socket can be connected to the
power outlet.
0809-002
1.2 Cable Connection
2-9
AKBEG-ID
1.3 Attachment of Micrometer
CAUTION
•
Do not give a strong shock to the micrometer
by hitting against human body or an object.
Otherwise, the micrometer may be damaged,
resulting in inaccurate adjustment of the
component pickup position.
•
T
ighten the setscrew until the micrometer can be
moved smoothly.
Excessive tightening may damage the
micrometer.
Attachment of Micrometer Connection of Micrometer Cable
Fig. B13 Attachment of Micrometer
Procedure
(1) Attach the micrometer to the measuring jig.
(2) Secure the micrometer with the setscrew.
(3) Connect the cable to the micrometer.
(4) Hold the end of the cable with your ngers and tighten the screw so that
no clearance can be left between the cable and the micrometer.
After the attachment is completed, check how the micrometer works.
1.3 Attachment of Micrometer
0809-002
2-10
AKBEG-ID
1.3.1 Replacement of Battery in Micrometer
(1) Put a coin, etc., in the groove of the battery lid and turn it in the
A-marked direction (counterclockwise) in the gure below until the lid
comes off.
(2) Take out the old battery.
(3) Put a new battery and set the lid. After that, turn the lid in the B-marked
direction (clockwise) to secure.
Notice
(a) When the battery is reset, the reference position is cleared.
(b) SR44 (Silver Oxide Button Cell Battery) must be used.
(c) When an error display appears or an error message such as "No
Counting" is issued, remove the battery once and set it back in place.
AA
B
B
Battery Lid
Fig. B14 Back Side of Micrometer
Procedure
1.3 Attachment of Micrometer
0809-002