4 Pneumatic and pressure control valve (PRV) 4.8 Replacing the force measuring unit and the trick and feather unit Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 59 Fig.104: Grub screw for fly wheel ►…

100%1 / 92
4 Pneumatic and pressure control valve (PRV)
4.8 Replacing the force measuring unit and the trick and feather unit
58 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020
4.8.3 Assembly
Fig.101: Screws fastening the force measuring unit
Fasten the force measuring unit to the
trick and feather unit.
Hand-tighten the two fastening screws.
 CAUTION!
Risk of short circuit!
Make sure that you fit the plastic
washer under the pipe holder.
.
 NOTICE!
Pipe holder!
Align the slit in the pipe holder so that
it is parallel to the edge of the printed
circuit board.
.
Fig.102: Connector
Disconnect the incremental encoder
and the D axis motor.
 CAUTION!
Do not damage the D axis connec-
tion!
The connector on the D axis cable is
easily damaged.
Plug in the connector with care. The
solder points could be easily damaged.
.
Fig.103: Spacer
Fit the two spacers with the short sides
facing upwards and hand-tighten these.
 NOTICE!
Third spacer!
If you are replacing the force measur-
ing unit, fit the third spacer.
.
4 Pneumatic and pressure control valve (PRV)
4.8 Replacing the force measuring unit and the trick and feather unit
Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 59
Fig.104: Grub screw for fly wheel
Fit the fly wheel and fix into place with
the two grub screws.
Fig.105: Fitting the rotary unit
Fit the rotary unit to the Z axis shaft
and hand-tighten the two screws.
 CAUTION!
Do not damage the incremental
disk!
The incremental disk is now access-
ible, down at the rotary unit.
Handle the rotary unit with care. The
incremental disk can be easily dam-
aged or contaminated.
.
Fig.106: Z axis motor connector
Connect the Z axis motor.
4 Pneumatic and pressure control valve (PRV)
4.8 Replacing the force measuring unit and the trick and feather unit
60 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020
Fig.107: Force transducer
Fit the force transducer. Fix carefully
into place with a screw.
 NOTICE!
Fit the adjustment wedge correctly!
The adjustment wedge has a curved
and a straight side.
Insert the adjustment wedge so that
the straight side faces the sensor.
.
Fig.108: Force measuring unit
Fix the force measuring unit into place
with the two fastening screws (hand-
tight).
Fig.109: Connecting the control cable
Connect the control cable and fix it with
the lock.
Fit the hose guidance, the flat ribbon baffle and the stopper.
3.3 "Replacing the hose and flat ribbon guide (Twin HF only)" [}23]
Fit the sleeve with ball fixing with a new seal.
4.6 "Replacing the sleeve with ball fixing/seal" [}43]