00197469-02_SM_Twin_Kunde_EN.pdf - 第7页
1 Introduction 1.2 Other instructions Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 7 1.2.4.3 Handling ESD modules As a general rule: Only touch electronic modules if you must carry out work on the mo…

1 Introduction
1.2 Other instructions
6 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020
1.2 Other instructions
1.2.1 Environmentally-friendly disposal of materials and components
Our products are manufactured using only materials and parts that can be easily separated and
disposed of in an environmentally-friendly way.
NOTICE
Observe the applicable regulations
The company operating the system has sole responsibility for the proper, environmentally-
friendly disposal of machines, working materials, consumable materials and wear parts.
► Please observe your national statutory provisions for waste disposal and environ-
mental protection.
1.2.2 Use of original accessories and spare parts
Only use original spare parts and authorized accessories. The use of other parts will affect safety
and will invalidate the liability for any consequential damage.
1.2.3 Information about this service manual
WARNING
Additional qualifications required
The service work described in this manual may only be performed by specially trained ser-
vice technicians, with appropriate qualifications and expertise.
If you should have any questions during the service work, please contact the SIPLACE customer
hotline directly or send an e-mail to hotline.siplace@asmpt.com.
1.2.4 ESD guidelines
1.2.4.1 What does ESD mean?
Fig.1: ESD label
Almost all of the modules in use today are equipped with highly integ-
rated Metal-Oxide-Semiconductor (MOS) blocks and components.
The manufacturing techniques used mean that these electronic com-
ponents are extremely sensitive to overvoltage and thus to electro-
static discharge.
The abbreviation for such modules is "ESD" (Electrostatic Sensitive
Device). "ESD" is used internationally. The following symbol on cab-
inet rating plates, racks or packaging indicates that components
which are sensitive to electrostatic discharge have been used and
thus that the modules concerned are also touch-sensitive.
ESDs can be destroyed by voltages and power levels that are far below the level that can be per-
ceived by humans. Such voltages occur if a person touches a component or module without
earthing themselves. Components that are exposed to such overvoltages do not generally appear
to be defective immediately - incorrect behavior starts after the component or module has been in
operation for some time.
1.2.4.2 Important measures to protect against static charging
► Most plastics can easily become charged and must therefore be kept away from at-risk com-
ponents.
► Always ensure that people, the workplace and packaging are safely earthed when handling
electrostatic sensitive components.

1 Introduction
1.2 Other instructions
Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 7
1.2.4.3 Handling ESD modules
As a general rule: Only touch electronic modules if you must carry out work on the modules. In that
case, make sure that you do not touch the pins or printed conductors when you pick up flat mod-
ules.
Only touch components if you are earthed by one of the following measures:
●
You are wearing an ESD wristband.
●
You are wearing ESD shoes.
●
You are wearing ESD shoe earthing strips on an ESD floor.
Immediately before you touch an electronic module, discharge your own body by touching a con-
ductive and earthed object (such as unpainted parts of a switch cabinet, a water pipe, etc.).
Do not allow modules with chargeable and highly insulating materials to touch one another, e.g.
plastic films, insulating table surfaces or items of clothing made from synthetic fibers.
Always place the modules on a conductive surface (table with an ESD coating, conductive ESD
foam, ESD bag or container).
Do not move the assemblies near to data view devices, monitors or television units. Keep a min-
imum distance of 10 cm to monitors.
1.2.4.4 Measurements and modifications to ESD modules
Only perform measurements on modules if one of the following conditions is fulfilled:
●
You are using an earthed measuring device (e.g. via PE conductors).
●
You are using a potential-free measuring device and discharge the measuring head before
the measurement (e.g.by touching an unpainted metal part of the controller casing).
► Always use an earthed soldering iron if you carry out any soldering work.
1.2.4.5 Dispatching ESD modules
► Always store modules and components in conductive packaging (e.g. metallized plastic bags
or metal sleeves) and dispatch them in conductive packaging
► If the packaging is not conductive, place the modules in a conductive envelope before pack-
aging. Use conductive expanded rubber, ESD bags, domestic aluminum foil or paper, for
example. NEVER use plastic bags or film.
► If the module has integral batteries, ensure that the conductive packaging does not touch or
short circuit the battery terminals and, if necessary, first cover the terminals with insulating
tape or material.
1.2.5 Validity of Document
This document contains service work instructions for all SIPLACE placement heads of type Twin,
Twin HF and Twin VHF.
The service work described in this manual is largely identical for all head types:
●
If the work required should differ from the standard procedure, this will be indicated with refer-
ence to the head type and delivery state.
●
Diagrams should be seen as examples e.g. the diagram of a SIPLACE Twin HF or a different
paint finish does not mean that the following information only applies to the type shown.
The manual focuses on describing mechanical service work.
Please refer to the circuit diagram folder for any electrical checks.
1.2.6 Release History
Release Amendments
07/2013 Initial release
07/2020 The document has been completely revised.
The placement heads Pick&Place module High Force R2 [03097486‑xx] and
Pick&Place module THK R2 [03097485‑xx] have been supplemented.

1 Introduction
1.3 Staff qualifications and training
8 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020
1.2.7 SIPLACE on the World Wide Web (WWW)
Log in to our SIPLACE® homepage at http://www.asm-smt.com.
You can choose between the German and English version.
The different sections contain information about our products, services and contact persons.
In addition, registered customers can also access the MySIPLACE user group. Here, you can
access special information about our placement systems, e.g.:
●
Technical documentation
●
Technical information
●
Spare parts lists
Registration for the MySIPLACE user group is very simple:
► Click on MyASM and then on Registrieren.
► Fill in the registration form and send it off to us.
Soon afterwards, you will receive your access authorization with user name and password.
1.3 Staff qualifications and training
Qualified or adequately trained personnel means that these people are familiar with the setting up,
operation and maintenance of the machine and the add-on devices and are suitably qualified, e.g.:
●
Have been trained, instructed or authorized to switch on and off, isolate, earth and identify
electrical circuits and system components in accordance with normal safety standards.
●
Have been trained or instructed in the upkeep and use of appropriate safety equipment in
accordance with normal safety standards.
1.4 Abbreviations
Abbreviations Description
PA, PA1, PA2 Placement area, Placement area 1, Placement area 2
CO Component
C&P Collect&Place
CPP Collect&Pick&Place head
CPx Collective term for CPP, CP20, CP12 and/or CP6
PRV Pressure control valve
ESD Electrostatic sensitive device
EMC Electromagnetic compatibility
FS Function state
The last two numbers form an item number.
HF High Force
HMK Head Maintenance Kit
PCB Board
P&P Pick&Place
TH TwinHead
VHF Very High Force