00197469-02_SM_Twin_Kunde_EN.pdf - 第78页

5 Boards and cables 5.5 Replacing the control cable 78 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 Installation ► Fit the head main board. 5.1 "Replacing the head main board" [ } 65] Fig.…

100%1 / 92
5 Boards and cables
5.5 Replacing the control cable
Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 77
Fig.137: Stopper for return unit and flat ribbon baffle (exam-
ple of Twin / TwinHF shown)
1. Stopper for return unit
2. Return unit buffer assembly
3. Flat ribbon baffle
Remove the two screws fastening the
stopper(1)
for the return unit.
Remove the flat ribbon baffle(3).
See also 3.3
"Replacing the hose and
flat ribbon guide (Twin HF only)" [}23]
Fig.138: Removing the control cable (example of Twin /
TwinHF shown)
Release the two locking levers on the
connector upwards and pull the control
cable(1)
carefully off the force meas-
urement board.
Remove the control cable from the
placement head.
5 Boards and cables
5.5 Replacing the control cable
78 Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020
Installation
Fit the head main board.
5.1 "Replacing the head main board" [}65]
Fig.139: Attaching the control cable (example of Twin /
TwinHF shown)
Reconnect the control cable to the
force measuring board(1)
.
Fig.140: Fitting the flat ribbon baffle and stopper for the re-
turn unit (example of Twin / TwinHF shown)
Place the flat ribbon baffle on to the
control cable.
Place the return unit stopper (2) onto
the flat ribbon baffle.
Insert the two screws(3) into the return
unit stopper.
Align the flat ribbon baffle to the control
cable.
 CAUTION!
The flat ribbon baffle and control
cable must run parallel to one an-
other(1)!
.
Follow the removal instructions in reverse order for further installation.
Also observe the installation instructions in the following section:
3.1 "Replacing the return unit buffer" [}17]
5 Boards and cables
5.6 Replacing the connector clamping piece
Service Manual SIPLACE TwinStar (Twin, Twin HF, Twin VHF) 07/2020 79
5.6 Replacing the connector clamping piece
Parts
Clamping piece for connector [03005851‑xx] (suitable for all Twin types)
Overview
Fig.141: Connector clamping piece
1. Clamping piece for connector
[03005851‑xx] (two per head)
Fastening screw [03013039‑xx]
(on the underside of the lens hood)
DIN EN ISO7380-M2.5x5-10.9, black
zinc
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
Removal
Remove the screw fastening the clamping piece on the underside of the lens hood and
remove the clamping piece.
Installation
Follow the removal instructions in reverse order for installation.