00197674-01-UM-E-Series-EN-12-2014.pdf - 第141页

User manual SIPLACE E 3 Technical data and assemblies From software version SC 708.0 12/2014 Edition 3.7 Vision system 141 3.7.3 Stationary compon ent camera, type 36 GigE Item no. 03112312-xx Stationary componen t camer…

100%1 / 308
3 Technical data and assemblies User manual SIPLACE E
3.7 Vision system From software version SC 708.0 12/2014 Edition
140
3.7.2 Component camera, type 30 GigE
Item no. 03101672-xx Component camera, type 30 GigE
3
Fig. 3.7 - 1 Component camera, type 30 GigE
(1) Component camera lens and illumination
(2) Camera amplifier
(3) Illumination control
3.7.2.1 Technical data
3
Component dimensions 0.3 mm x 0.3 mm to 27 mm x 27 mm
Component range 03015 to 27 mm x 27 mm
PLCC, SO, QFP, TSDP, SOT, MELF, CHIP, IC BGA
Min. lead pitch 0.3 mm
Min. lead width 0.15 mm
Min. ball pitch 0.25 mm for components < 18 mm x 18 mm
0.35 mm for components < 18 mm x 18 mm
Min. ball diameter 0.14 mm for components < 18 mm x 18 mm
0.2 mm for components < 18 mm x 18 mm
Field of vision 32 mm x 32 mm
Illumination type Front-illumination (5 levels, programmable as required)
User manual SIPLACE E 3 Technical data and assemblies
From software version SC 708.0 12/2014 Edition 3.7 Vision system
141
3.7.3 Stationary component camera, type 36 GigE
Item no. 03112312-xx Stationary component camera, type 36 GigE
3.7.3.1 Structure
3
Fig. 3.7 - 2 Structure for the stationary P&P component camera, type 36 GigE
(1) Camera housing with integral camera
and camera amplifier
(2) Glass plate - over the illumination and
lens levels
3 Technical data and assemblies User manual SIPLACE E
3.7 Vision system From software version SC 708.0 12/2014 Edition
142
3.7.3.2 Technical data
3
Component dimensions 0.8 x 0.8 mm² to 32 x 32 mm² (single measurement)
Range of components 0603, MELF, SO, PLCC, QFP, electrolytic capacitors, BGA
Min. lead pitch 0.4 mm
Min. lead width 0.24 mm
Min. ball pitch 0.56 mm
Min. ball diameter 0.32 mm
Field of vision 38 x 38 mm²
Method of illumination Front-illumination (6 levels, programmable as required)