6 Station extensions User manual SIPLACE E 6.1 Nozzle changer From software version SC 708.0 12/2014 Editio n 276 6 Fig. 6.1 - 17 Nozzle magazin for the SIPLACE CP6 (1) 12 garages for 39xx nozzles (2) Fiducials (only vis…

User manual SIPLACE E 6 Station extensions
From software version SC 708.0 12/2014 Edition 6.1 Nozzle changer
275
6.1.4.1 Description
This nozzle changer can accommodate 4 magazines, each with 6 nozzle garages.
The magazines are seated on a common support. They are centered with two parallel pins and
fixed in place with 4 push buttons. The exact position is determined with two fiducials on each
magazine. The correct seat of the magazines on the basic nozzle changer body is monitored by
microswitches, to prevent a collision of the placement head with any magazines projecting up-
wards. All magazine locations must be filled since the safety circuit stops the machine in response
to missing magazines or magazines that are not seated correctly.
At the installed nozzle station, components can be blown off the nozzles of the SIPLACE CP6 and
nozzles stripped off and rejected.
6
6
Fig. 6.1 - 16 Nozzle changer magazin for the SIPLACE SIPLACE CP6
(1) 6 garages for 38xx nozzles
(2) Fiducials (only visible when locking plate open)
CAUTION
Only use the magazine for the SIPLACE SIPLACE CP6 together with the SIPLACE
CP6.
(1)
(2)
(2)

6 Station extensions User manual SIPLACE E
6.1 Nozzle changer From software version SC 708.0 12/2014 Edition
276
6
Fig. 6.1 - 17 Nozzle magazin for the SIPLACE CP6
(1) 12 garages for 39xx nozzles
(2) Fiducials (only visible when locking plate open)
(1)
(2)
(2)

User manual SIPLACE E 6 Station extensions
From software version SC 708.0 12/2014 Edition 6.1 Nozzle changer
277
6.1.4.2 Technical data
6
Nozzle changer for the SIPLACE CP6
Number of nozzle holders
38xx
39xx
24
48
Number of nozzle magazines 4
Nozzle types 38xx/39xx
Nozzle changeover time Approx. 2s per nozzle
Compressed air connection 0.45 MPa (4.5 bar)