00197674-01-UM-E-Series-EN-12-2014.pdf - 第78页
2 Operational safety User manual SIPLACE E 2.7 Safety features From software version SC 708.0 12/2014 Editi on 78 Function 2 If the protective cover is swung upwards, the po wer supply to t he gantry axes will be immedia…

User manual SIPLACE E 2 Operational safety
From software version SC 708.0 12/2014 Edition 2.7 Safety features
77
2.7 Safety features
2.7.1 Protective covers
The protective hoods and covers serve as protective devices which prevent unauthorized access
to the inside of the machine.
2
2
Fig. 2.7 - 1 Protective covers
(1) Protective cover location 1
(2) Protective cover location 2
The travel range of the gantry is protected with two covers which can be opened (items 1 and 2).
CAUTION
Risk of damage!
The protective covers and other covers could be damaged if too much force is exerted.
Do not stand on or climb up the protective covers and other covers.
(1)
(2)

2 Operational safety User manual SIPLACE E
2.7 Safety features From software version SC 708.0 12/2014 Edition
78
Function 2
If the protective cover is swung upwards, the power supply to the gantry axes will be immediately
interrupted. The gantry axes stop moving. The message "Close cover" is displayed on the screen.
Close the protective covers and press the START button (item 2 in fig. 2.7 - 2), to continue
placement.
2
Fig. 2.7 - 2 Position of the start buttons (white) on the machine
(1) STOP button (black) on machine
(2) Start button (white) on the machine
(3) EMERGENCY STOP button
(2)
(1)
(3)

User manual SIPLACE E 2 Operational safety
From software version SC 708.0 12/2014 Edition 2.7 Safety features
79
2.7.2 Switches and buttons on the machine
2.7.2.1 Position of switches and buttons on the machine
2
Fig. 2.7 - 3 Position of switches and buttons - location 1
(1) Main switch
(2) Stop button (black)
(3) Start button (white)
(4) EMERGENCY STOP button
No main switch on location 2
(2)
(1)
(3)
(4)