00198051-01_IM_SetupCenter_8.0_EN.pdf - 第15页

System Components and Configurations 3.2.6 Recommended Installation Scenarios System Configuration Installation Manual SIPLACE Setup Center 8.0 15 3.2.6.2 3 . 2 . 6 . 2 C e n t r a l D a t a b a s e Central Database Syst…

100%1 / 112
System Components and Configurations
System Configuration 3.2.4 Forced Setup Verification
14 Installation Manual SIPLACE Setup Center 8.0
3.2.4
3.2.4 Forced Setup Verification
Forced Setup Verification
Activate the forced setup verification at the placement station if it is necessary.
3.2.5
3.2.5 Docking Stations
Docking Stations
The installation of the docking station is required, if E-, X- or SX tables are used and a pre setup area or
kitting area exists.
3.2.6
3.2.6 Recommended Installation Scenarios
Recommended Installation Scenarios
3.2.6.1
3.2.6.1 Local Database
Local Database
Usually the system configuration "Local Database" is for a small manufacturing facility with one ore two
production lines. An assumption for the configuration is that the SIPLACE Pro database is also installed
locally. The Setup Center GUI is directly connected to the local SIPLACE Pro and local Setup Center
Database and manages the setup verification for the stations connected via the SIPLACE LAN.
This scenario can also be used, if a step-by-step introduction is helpful. Then it may also helpful to omit
the "Forced Setup Verification" activation and to start with the unforced setup verification. After a definite
time the forced setup verification can be activated at station and Setup Center.
System Components and Configurations
3.2.6 Recommended Installation Scenarios System Configuration
Installation Manual SIPLACE Setup Center 8.0 15
3.2.6.2
3.2.6.2 Central Database
Central Database
System configuration Central Database
Usually the system configuration "Central Database" is for manufacturing facility with more than one pro
-
duction line. Prerequisites for the configuration is
the SIPLACE Pro database is also installed centrally, or
the SIPALCE EDM product is deployed, or
a pre setup area with Setup Center is planned, or
packaging units often moves between different placement lines.
The Setup Center GUIs are connected to the local SIPLACE Pro and to the central Setup Center Data
-
base. The docking stations are connected via CAN-Bus to the SC Computer. The pre setup unit is the
reason, why a central Setup Center Database is necessary.
System Components and Configurations
System Configuration 3.2.6 Recommended Installation Scenarios
16 Installation Manual SIPLACE Setup Center 8.0