Barcode-Scanner Installation 6.2.1 Datalogic Scanner’s Cradl e BC-8030 (Narrowband) Datalogic Scanner Installation Manual SIPLACE Setup Center 8.0 55 The scan ner must have an a ddress (tem porary "0000"), so t…

Barcode-Scanner Installation
Datalogic Scanner 6.2.1 Datalogic Scanner’s Cradle BC-8030 (Narrowband)
54 Installation Manual SIPLACE Setup Center 8.0
► Scan the barcode "RS-232 Standard" to set the interface to RS-232.
The cradle is now ready for use with Setup Center.
6.2.1.2
6.2.1.2 Connect cradle via USB
Connect cradle via USB
Installation of the USB-COM driver
For connection via USB, you must install the USB-COM driver first.
The installation packages for 32 bit and 64 bit operating systems are located in the “\3rdparty install
-
er\Datalogic\USB-COM Driver” directory of the Setup Center installation CD. For installation please refer
to "6.2.6 Installation of the USB-COM driver" [ ➙ 67].
Steps to configure the cradle to the USB-COM interface
The device may be configured to a different interface ex factory, the following steps switch to USB-COM
port.
► Please scan the following barcodes in the order they are printed:
The standard configuration of the scanner is restored.
► Scan the barcode “0” four times.

Barcode-Scanner Installation
6.2.1 Datalogic Scanner’s Cradle BC-8030 (Narrowband) Datalogic Scanner
Installation Manual SIPLACE Setup Center 8.0 55
The scanner must have an address (temporary "0000"), so that it can get connected to the cradle. This
address will be changed / set again later by Setup Center with the automatic configuration.
In order to configure the cradle a scanner needs to be bound to the cradle with the barcode "Bind".
► Scan the barcode "Bind" now.
► If the green LED of the scanner blinks, put the scanner into the cradle.
► The green LED is now switched off and the scanner is already registered on the cradle.
The interface of the cradle can be set up now with the following barcodes.
► Scan the barcode "Restore BC-80X0 Default" to restore the standard configuration of the cradle.
► Scan the barcode "USB-COM" to set the interface to USB.

Barcode-Scanner Installation
Datalogic Scanner 6.2.2 Datalogic Scanner`s Cradle BC-9030 (Narrowband)
56 Installation Manual SIPLACE Setup Center 8.0
The cradle is now ready for use with Setup Center.
The communication over the USB-COM interface requires at least the firmware version 610001601 for
the scanner cradle.
6.2.2
6.2.2 Datalogic Scanner`s Cradle BC-9030 (Narrowband)
Datalogic Scanner`s Cradle BC-9030 (Narrowband)
The Datalogic scanner’s cradle BC-9030 needs to be connected to the Setup Center PC. The cradle in
-
corporates a multi-standard interface, which can be connected via USB or RS-232 to a PC.
The label on the cradle contains LED indicators and a multi-function button (1). When the multi-function
button is pressed for less than 5 seconds, the cradle will transmit a “broadcast” message. When the
broadcast is sent, all properly configured and online scanners that are linked to that cradle and within
radio range will emit a beep and blink within 5 seconds. This functionality is useful to:
▪ Verity which scanners are linked to a certain cradle
▪ Detect a scanner forgotten somewhere
When the multi-function button is pressed for longer than 5 seconds, all paired scanners will be unpaired.
NOTICE