00198051-01_IM_SetupCenter_8.0_EN.pdf - 第83页
Docking Station Installation 7.2.1 CAN Bus Address of the Docking Station Safety Instructions Installation Manual SIPLACE Setup Center 8.0 83 7 7 D o c k in g S t a t io n I n s t a lla t io n Docking Station Installatio…

Barcode-Scanner Installation
Motorola Scanner 6.3.5 Motorola / Symbol Scanner Configuration
82 Installation Manual SIPLACE Setup Center 8.0
Setting 1D or 2D barcodes for Mobile Scanners
► Select the Barcode tab
► Choose the allowed 1D or 2D barcodes for your mobile scanner here.
► Select the barcode and press Edit to open the additional barcode settings.
► Press Ok to save the settings.
NOTICE
Context menu
Click and hold on a barcode to open the context menu:
All Off: Select none of the barcodes in the list
All On: Select all the barcodes in the list

Docking Station Installation
7.2.1 CAN Bus Address of the Docking Station Safety Instructions
Installation Manual SIPLACE Setup Center 8.0 83
7
7 Docking Station Installation
Docking Station Installation
To obtain more details about using the docking station for E-, X- or SX tables, please refer to the current
version of the operating manual.
7.1
7.1 Safety Instructions
Safety Instructions
7.2
7.2 Connections on the Docking Station
Connections on the Docking Station
7.2.1
7.2.1 CAN Bus Address of the Docking Station
CAN Bus Address of the Docking Station
You need to set a CAN Bus address for each docking station. This CAN Bus address must be different
for each docking station.
► Set the CAN Bus address for the docking station.
Docking station: CAN bus addresses
► Make sure that you only assign each address once, when setting the CAN Bus address.
DANGER
Make sure that nobody is using the connected change over table, when you switch the power
on.
The device must not be opened or tampered with.
WARNING
Do not connect the device during placement or when installed inside the placement machine.
DANGER
Never cover the air discharge opening in the integrated fan and the ventilation slits on the side
of the device!
Covering these could lead to overheating and destruction of the power pack.

Docking Station Installation
Connections on the Docking Station 7.2.2 Data Connection of the Docking Station
84 Installation Manual SIPLACE Setup Center 8.0
7.2.2
7.2.2 Data Connection of the Docking Station
Data Connection of the Docking Station
Establish a data connection between the docking station and the Setup Center PC. This data connection
is realized via a CAN Bus. Ensure that you have already installed the CAN card in your PC.
Connect the CAN cable to the docking station and the PC. This CAN cable has 5 connections, one of
which you can use for the PC. This leaves 4 other connections, allowing you to connect up to 4 docking
stations with this cable.
► Connect the CAN cable to the CAN connection at your docking station. This can be found on the
back of the docking station.
► Connect the CAN cable to the CAN card on the PC (CAN Bus 1 or 2).
See the connection scenarios below for CAN Bus cable connection.
Docking Station X
1. CAN Bus Address Switch
2. CAN Connection
Docking Station SX
1. CAN Bus Address Switch
2. CAN Connection